Automated Solid Phase Extraction System BSPE-201, ESMC, Biolab, Canada
$5,100,000.00
Automated Solid Phase Extraction System BSPE-201, Biolab, Canada
- Series: 200
- Model: BSPE-201, BSPE-202, BSPE-203, BSPE-204
- Brand: Biolab
- Origin: Canada
- Manufacturer: Biolab Scientific
Automatic solid phase extraction series adopts highly integrated pipeline design, with multi-function sample needle, relying on precise and flexible mechanical arm to improve sample preparation efficiency and bring you convenient and easy working experience, Let your work be faster.
- The injection needle and the extraction column are sealed by a univer sal plug sealing structure and equipped with H-axis pressing block to ensure good sealing.
- The suspension structure is adopted in the test tube bracket, which ensures the positioning accuracy of the manipulator to the greatest extent.
- The instrument standard router can be connected by WiFi or network line, which fully realizes the whole process of automation and unattended.
- Using modular design, only one communication line and pipeline can work between modules, and it is convenient to replace and maintain.
Applications
Research, Analytical laboratories, HPLC, GCMS, HPLC-MS
Features
- The injection needle and the extraction column are sealed by a univer sal plug sealing structure and equipped with H-axis pressing block to ensure good sealing.
- The suspension structure is adopted in the test tube bracket, which ensures the positioning accuracy of the manipulator to the greatest extent.
- The instrument standard router can be connected by WiFi or network line, which fully realizes the whole process of automation and unattended.
- Using modular design, only one communication line and pipeline can work between modules, and it is convenient to replace and maintain.
- Add emergency stop button, when the instrument is abnormal, manual operation can be emergency stop, to maximize user safety.
- Handwheel adjusting origin greatly saves the time of adjusting origin.
- Number of channels and control mode: The instrument host adopts modular design, supports the number of channels upgraded in the field, and supports 1/2/4/6/8 multiple channel combinations;
- Continuous processing capacity: Maximum continuous processing capacity of 52-bit samples;
- Robot arm: X/Y/Z three-dimensional manipulator design, X/Y axis linkage, improve operational
- efficiency; H axis is added to move the slider, giving consideration to flexible movement and accurate positioning;
- Sample pump: Sampling accuracy, solvent corrosion resistance, high pressure resistance(maxi mum withstand voltage 1Mpa), and compatible with size and volume sampling;
- Sample needle:316L stainless steel, solvent resistant; unique side-bottom opening to ensure full
- sample loading; highly integrated function for liquid channels, gas channels, and for extraction column seals;
- Remote connection and control: The instrument is equipped with a router that can be connected via Wi-Fi or network cable, which fully realizes the whole process of automation and unattended operation;
- Puncture sampling: Sample needle can be selected to realize puncture sampling and avoid sample volatilization loss;
- Sample volume and receiving volume: The whole series supports 10 – 20mL sample tube, and can support 50mL and larger specifications within two channels; the receiving volume is standard 10mL/15mL, and the two channels can be expanded by 50mL;
- Pressure sensing: Each channel is equipped with a standard pressure sensor, push column pressure to achieve closed-loop fuzzy control, and has the functions of overpressure alarm and termination of the experiment;
- Velocity control: The top of each extraction column is equipped with an independent sealing cap. The high pressure sealing is realized by docking with the sample needle and moving Z-axis pressure block. The solution passes through the extraction column according to the set flow rate to ensure good reproducibility and parallelism;
- Solvent management system: Supporting 8 reagents; Supporting the hint function of insufficient residual capacity; Supporting liquid level following function;
- Infiltration and incubation: When the active solvent or eluting solvent is loaded into the extraction column, the liquid level can be kept above the packing for a certain time to ensure full activation or elution and to ensure the ideal experimental results;
- Cleaning mode: Supporting various cleaning modes to ensure that the inner and outer walls of sample needles are clean without cross-contam ination;
- Waste discharge passage: Support environmental protection to recover waste liquor and separate treatment of waste liquor with different
- Properties;
- Specification of extraction column: Compatible with conventional 1/3/6mL extraction column, other specifications of extraction column can be
- customized according to requirements;
- Multi-scheme extraction: Supporting the simultaneous operation of different specifications of extraction columns and different treatment
- projects without waiting, improving the efficiency of continuous treatment;
- A/B column extraction: Support multi-mode tandem column extraction, automatic identification of A/B column extraction scheme;
- Online drying/dewatering: Supporting on-line nitrogen purge mode;
- Online Concentration: Supporting in-situ nitrogen purge and concentration, the concentration time can be edited;
- Large volume injection: Supports the continuous and smooth loading of more than 500 mL samples without interruption, particle wear
- resistance, corrosion resistance, no need for any consumables and regular maintenance; supports the continuous switching of samples, the number of samples larger than 48 bits;
- Cloud services: Supporting upload and download programs and parameters; Supporting online technical support and exchange; Supporting remote monitoring;
- Booking starts: After editing the experimental scheme, the start-up time can be self-booked according to the time of the analyzer;
- Count down: After the beginning of the experiment, the countdown time is used to facilitate the control of the end time of the experiment and to
- match the time of the analyzer in advance;
- Intelligent self-check and alarm: After the parameter setting is completed, the software self-checks whether there are logic errors, promptly
- reminds the modification; Intelligent fault alarm system, according to the fault level, chooses to continue or stop
- Number of channels and control mode: The instrument host adopts modular design,
Specification
Channels |
1 |
Channel Independent Control |
Support |
Sample pump |
Precision Continuous Sample Pump |
Pump flow rate |
0.1-120 mL/min |
Types of solvents |
8 Seed, 500 mL Solvent Bottle |
Sample volume |
0.1 mL-20L |
Sample tube volume |
10 – 20 mL,customization |
Receiving volume |
10mL/15 mL, other specifications customized |
Puncture sampling |
Supporting |
Loading mode |
X/Y/Z Three-Dimensional Manipulator |
Accuracy of manipulator |
0.01 mm |
Sealing technology |
Docking Technology of Independent Seal Cover and Pan-plug Seal |
Extraction mode |
Positive pressure extraction |
column pressure |
≤80 psi |
Pressure sensing |
Support, Over voltage Alarm, Threshold Editable (5-145psi) |
Column drying method |
Nitrogen purge |
Waste collection |
Branch collection, 3 channels |
A/B in series |
Support, A/B Pillar |
Cleaning mode |
Nitrogen purge, solvent cleaning, blowing stirring cleaning and other modes are used to clean the inner and outer walls of sample needles. |
Liquid level following |
Support |
Solvent Residual Capacity |
Solvent deficiency hints |
Host Size (HxWxD) |
680 mmx580 mmx670 mm |
Voltage |
220/110 V, 50/60 Hz |
working temperature |
5-40Temperature |
Working humidity |
0-90% without condensation |
power |
60 W |