elitetradebd,elitescientific,elitescientific&meditech,elitescientific&meditechco,elitetrade,elite,elitescientificco,elitechemicalsco,elitewebsite,elitelabequipments,elitelaboratories,labgoods,bdscientific,scientificcoinbd

Online total manganese analyzer, TMnG-3061

$0.00

#Online total manganese analyzer

#Total manganese analyzer #TMnG-3061 #Manganese analyzer

#TMnG-3061  ONLINE TOTAL MANGANESE ANALYZER

The online automatic total manganese analyzer is an optical method heavy metal online analyzer designed according to national environmental protection standards. It is applied to the simultaneous online analysis of various heavy metal elements in surface water, industrial process water and industrial wastewater. The measured heavy metal elements include environmental protection. The first and second categories of heavy metal prevention and control projects in the 12th Five-Year Plan for Comprehensive Prevention and Control of Heavy Metal Pollution.

Working principle
The water sample is dissolved under the high temperature of the oxidant, and after cooling, a color complex is formed with the color developer. The analyzer detects the change of the color
and converts the change into the total manganese value. The amount of colored complex formed is equivalent to the amount of total manganese.

Technical parameters

Product TMnG-3061 Online Total Manganese Analyzer
Standard Potassium periodate spectrophotometry
Measuring range 0.00-5.00 mg/L
Accuracy ≤±10% when ≥0.2mg/L; ≤±0.02mg/L when <0.2mg/L
Repeatability ≤±5%
Stability ≤±10% in 24 hours
Measurement period The minimum measurement period is 50 minutes, according to the actual water sample, The digestion time can be modified from 5 to 120 minutes.
Sampling period Time interval(55~9999min adjustable by yourself) and Integral time measurement mode;
Calibration period Adjustable in 1~99days;
Maintenance period Usually one time per month and 30 minutes each time
Output 4~20mA( 2 ways) RS232,RS485
Ambient requirement It should be indoor and temperature can be adjustable. The recommend temperature is +5~28℃;humidity≤90%(no dew)
Power AC220±10% V,50±10% Hz,5 A;
Dimension size Height 1450×Width510×Length 450 mm;
Data saved The data can be saved when abnormal alarms and power off.
Display Touch screen and Command Input
Other When Reset after abnormal alarm and power on after off, the instrument automatically discharges residual reactants in the instrument and automatically resumes working status.