Soxhlet apparatus

$0.00
Soxhlet apparatus, Behr KEX 250

The Behr R 104S-SK Soxhlet Extractor with single-row sample arrangement is an inexpensive and practical solution for classic Soxhlet and fat extraction.
Distinctive features of R-series Soxhlet extraction machines:
– Each place is regulated separately.
– Water cooling system contributes to uniform cooling.
– Convenient stand to store the cooler between extractions.
– Clamps for secure fastening of individual parts of the apparatus after removing the sample container.
– Models “S”: equipped with an additional tap, which eliminates the need for distillation after extraction.
Technical characteristics of the apparatus for Soxhlet extraction Behr R 104S-SK:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 1500 W
– Weight: 15 kg
– Dimensions (LxWxH): 53x32x74 cm
– Expansion in a row into 4 samples
– Extractor volume: 100 ml
– Flat-bottomed flasks

Accessories:

Categories:  

Soxhlet apparatus

$0.00
Soxhlet apparatus with tap, Behr KEX 100F

Behr Soxhlet Extractors are a good choice to meet the demands of modern laboratories.
Using the hydrolysis module (1, 4 or 6 places), it is possible to digest samples with acid before extraction (determination of the total fat content by the Weibull-Stoldt method).
Distinctive features of Behr Soxhlet extractors:
– Volume from 30 ml to 2000 ml
– Compact apparatus for one flask
– Apparatus with in-line arrangement for 4 or 6 places
– The design of the extractors with a specially designed curved tube allows to achieve a uniform process at all locations …
– Thanks to the tap, additional distillation is eliminated.
Fully equipped compact extraction systems include:
– Main stand (stand)
– Heating device
– Mountings
– Hoses
– Glass apparatus (reaction flask, extractor with tap, Dimroth cooler).
Technical characteristics of the Behr KEX 100F Soxhlet extraction apparatus:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 450 W
– Weight: 7.5 kg
– Dimensions (LxWxH): 23x33x80 cm
– Extractor volume: 100 ml
– Extractor with tap

Accessories:

Soxhlet extraction

$0.00
Soxhlet extraction apparatus Behr KEX 1000F, extractor with tap

Behr Soxhlet Extractors are a good choice to meet the demands of modern laboratories.
By means of the hydrolysis module (for 1, 4 or 6 places), it is possible to digest the samples with acid before extraction (determination of the total fat content according to the Weibull-Stoldt method).
Distinctive features of Behr Soxhlet extractors:
– Volume from 30 ml to 2000 ml
– Compact apparatus for one flask
– Apparatus with in-line arrangement for 4 or 6 places
– The design of the extractors with a specially designed curved tube allows to achieve a uniform process at all locations …
– Thanks to the tap, additional distillation is eliminated.
Fully equipped compact extraction systems include:
– Main stand (stand)
– Heating device
– Mountings
– Hoses
– Glass apparatus (reaction flask, extractor with tap, Dimroth cooler).
Technical characteristics of the Behr KEX 1000F Soxhlet extraction apparatus:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 1100 W
– Weight: 8.5 kg
– Dimensions (LxWxH): 23x35x95 cm
– Extractor volume: 1000 ml
– Extractor with tap

Accessories

Categories:  

Randall extraction

$0.00
Randall extraction machine, Behr E6

Behr’s Randall extraction systems provide fat determination up to 5 times faster than conventional Soxhlet extraction systems.
The scope of delivery includes 1 set of extraction tubes per 100 ml.

– Optimum safety is ensured by the threaded attachment of the extraction devices.
– Each heating sample has a separate temperature control
– Each extraction tube with sample can be independently moved
– Possibility to lower / raise all samples using 1 lever
Technical characteristics of the Behr E6 Randall Extractor:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 2160 W
– Weight: 50 kg
– Dimensions (LxWxH): 85x42x67 cm
– 6 samples
– Volume: 60 ml, max. 75 ml
– 4 samples
– Volume: 60 ml, max. 75 ml

Accessories

  • Porous material for Kjeldahl decomposition Behr SIST 100, 100 g
  • Extraction cup Behr EB 75, 75 ml
  • Extraction thimbles Behr EX 75HS
  • Supplier in Bangladesh- Elite Scientific & Meditech Co.
  • For any queries visit us- www.elitetradebd.com
Categories:  

Randall extraction

$0.00
Randall Extraction Machine, Behr E4

Behr’s Randall extraction systems provide fat determination up to 5 times faster than conventional Soxhlet extraction systems.
The scope of delivery includes 1 set of extraction tubes per 100 ml.
Distinctive features of the Behr Randall extraction systems:
– Optimum safety is ensured by the threaded fastening of the extraction devices.
– Each heated sample has a separate temperature control.
– Each extraction tube with a sample can be independently moved.
– Possibility to lower / raise all samples using 1 lever.
Behr E4 Randall Extractor Specifications:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 1440 W
– Weight: 34 kg
– Dimensions (LxWxH): 55x42x67 cm
– 4 samples
– Volume: 60 ml, max. 75 ml

Categories:  

Randall extraction

$0.00
Randall extraction machine, Behr E1

Behr E1 Randall Extraction Machine
Behr’s Randall extraction systems provide fat determination up to 5 times faster than conventional Soxhlet extraction systems.
The scope of delivery includes 1 set of extraction tubes per 100 ml.
– Optimum safety is ensured by the threaded attachment of the extraction devices.
Technical characteristics of the Behr E1 Randall Extractor:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 360 W
– Weight: 6 kg
– Dimensions (LxWxH): 23x37x60 cm
– 1 sample
– Volume: 60 ml, max … 75 ml

Accessories

  • Porous material for Kjeldahl decomposition Behr SIST 100, 100 g
  • Extraction cup Behr EB 75, 75 ml
  • Extraction thimbles Behr EX 75HS
  • Supplier in Bangladesh- Elite Scientific & Meditech Co.
  • For any queries visit us- www.elitetradebd.com
Categories:  

Tissue determination apparatus

$0.00
Raw tissue determination apparatus, Behr EXR 6

Apparatus for hydrolysis or determination of raw tissue Behr EXR 6

The Behr EXR 6 in-line hydrolysis apparatus is used to heat aqueous solutions of samples held in beakers, in particular for
• determination of crude fiber in accordance with ISO 6865 (“Veende method”)
• carrying out a hydrolysis step for determination of total fat content (ISO 11085)
• hydrolysis of fats by the Weibul-Stoldt method.
Depending on the model and configuration, the apparatus consists of four or six individually adjustable heating slots for 600 ml beakers. They are cooled by cold finger immersion chillers installed at the top of the bowls, which are fed with water from a cooling water distributor.
Method Weibull-Stoldt method.
The quantification of the fat content of food is carried out using solvent extraction. “Free fats” are determined by direct extraction.
The mass fraction of fat contains, in addition to “free fats” – “bound fats”, which are released by acid breakdown.
The delivery set of the Behr EXR 6 hydrolysis apparatus includes:
– R 6 heater in-line (6 heaters)
– Vertical supports: 2 pcs
– Cooling water distributor with a stand for coolers (6-seat) with a tray
– Water supply hose, polyamide, Ø 8 mm
– Water drain hose, PVC, Ø 12 mm
– Tool for disconnecting quick couplings
– Water tap connection with 3⁄4 “thread
– Tap adapter with 1⁄2 “thread The
following hydrolysis accessories are included, depending on model and configuration:
– 4 600 ml
beakers , tall shape – 4 cold finger coolers for 600 ml beakers
– 8 Silicone tubes 6 x 2 mm, length 50 cm
In addition, depending on the type of analysis that you intend to carry out, you will need:
– Filtering device:
– for hydrolysis: FU 6 (Art. B00441144)
– for determination of wet tissue: SC6 (Art. B00513780)
– Drying     oven
– Analytical balance
– For determination of fat content: Extraction device
– For determination of crude fiber: muffle furnace

Accessories

Behr FU 6 hydrolysis filter device, borosilicate glass

Filtration device for device for determination of wet tissue Behr SC 6

Categories:  

Automatic distillation

$0.00
Automatic steam distillation unit Behr S5
Automatic steam distillation unit automatic feeding of NaOH, H2O and H3BO4

Behr automatic steam distillation units ensure high productivity and reliability in daily operation.
The Behr S series automatic steam distillation units are the ideal complement to the digester for Kjeldahl nitrogen analysis.
Depending on the need, you can choose one of five steam units. Their basic design is identical, they differ only in the degree of comfort and automation.
All steam distillation units are equipped with:
– A safety switch as a main switch that automatically trips in the event of a reset and short circuit
– A mechanical safety valve to protect against excessive pressure in the
steam generator – A vessel monitoring device
– A door switch that automatically shuts off the distiller when the door
is opened – A resettable thermostat to prevent overheating
– A pneumatic switch to control the cooling circuit
– A temperature-dependent steam heating phase and a magnetic valve for pressure control
Features of the Behr S5 automatic steam distillation unit:
– Maximum safety and reliability
– Robust polyurethane housing, insensitive to external influences
– Distillation time approx. 3 minutes per sample
– Detection limit 0.2 mg N
– Re-detection rate> 99.5%
– Reproducibility +/- 1%
– Adjustable steam output 40-100%
– One-button control system
– Programmable reaction time
– Programmable distillation time
– USB port
– Fill level control for a set of canisters
– Automatic aspiration of sample residues
– Possibility to connect to a titrator
Technical characteristics of the automatic steam distillation unit Behr S5:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 1700 W
– Cooling fluid consumption: 5 l / min
– Distillation time: 2-4 min. for sample
– Spare tank: KAS 20
– Port: USB
– Programs: 100
– Dimensions (WxHxD): 41×67.5×41
– Weight: 35 kg
– Connection to the titrator: yes
Equipping the Behr S5 automatic steam distillation unit:
– Automatic addition of H2O: yes
– Automatic addition of NaOH: yes
– Automatic addition of H3BO2: yes
– Manual addition of H2O: yes
– Manual addition of NaOH: yes
– Manual addition of H3BO2: yes
– Automatic aspiration of sample residues: yes
– Number of programs: 99
– Ability to connect to a titrator: yes

  • Supplier in Bangladesh- Elite Scientific & Meditech Co.
  • For any queries visit us- www.elitetradebd.com
Categories:  

Distillation unit

$0.00
Automatic steam distillation unit, Behr S4
Automatic steam distillation unit automatic feeding of NaOH, H2O and H3BO4, Behr S4

Behr automatic steam distillation units ensure high productivity and reliability in daily operation.
The Behr S series automatic steam distillation units are the optimal addition to a digestor for Kjldahl nitrogen analysis.
Depending on the need, you can choose one of five steam units. Their basic design is identical, they differ only in the degree of comfort and automation.
All steam distillation units are equipped with:
– A safety switch as a main switch that automatically trips in the event of a reset and short circuit
– A mechanical safety valve to protect against excessive pressure in the
steam generator – A vessel monitoring device
– A door switch that automatically shuts off the distiller when the door
is opened – A resettable thermostat to prevent overheating
– A pneumatic switch to control the cooling circuit
– A temperature-dependent steam heating phase and a magnetic valve for pressure control
Features of the Behr S4 automatic steam distillation unit:
– Maximum safety and reliability
– Robust polyurethane housing, insensitive to external influences
– Distillation time approx. 3 minutes per sample
– Detection limit 0.2 mg N
– Re-detection rate> 99.5%
– Reproducibility +/- 1%
– Adjustable steam output 40-100%
– One-button control system
– Programmable reaction time
– Programmable distillation time
– USB port
– Fill level control for a set of canisters
– Automatic aspiration of sample residues
Technical characteristics of the automatic steam distillation unit Behr S4:
– Voltage: 230 V
– Frequency: 50/60 Hz
– Power: 1700 W
– Consumption of coolant: 5 l / min
– Distillation time: 2-4 min. for sample
– Spare tank: KAS 20
– Port: USB
– Programs: 100
– Dimensions (WxHxD): 41×67.5×41
– Weight: 35 kg
– Titrator connection: no
Equipping the Behr S4 automatic steam distillation unit:
– Automatic addition of H2O: yes
– Automatic addition of NaOH: yes
– Automatic addition of H3BO2: yes
– Manual addition of H2O: yes
– Manual addition of NaOH: yes
– Manual addition of H3BO2: yes
– Automatic aspiration of sample residues: yes
– Number of programs: 99
– Possibility of connecting to a titrator: no

Accessories

Canister set Behr KAS 40, 4 canisters, 20l each

  • Supplier in Bangladesh- Elite Scientific & Meditech Co.
  • For any queries visit us- www.elitetradebd.com
Categories:  

Distillation unit

$0.00
Steam distillation unit for determination of volatile acids
Distillation unit for determination of volatile acids Behr D2

Steam distillation unit Behr D2 for the determination of volatile acids in wine and other alcoholic beverages, complete with glass parts, volumetric flasks.
Distillers D1 and D2 are especially suitable for large sample volumes.
The software for Windows provides data exchange on the parameters of the distiller operation to the computer and back through the RS-232 interface.
A library with typical tasks is supplied on CD. If necessary, the data can be displayed in the form of a graph.

Scopes of the Behr D2 steam distillation unit:

– alcohol distillation;
– determination of volatile organic acids;
– control of fermentation processes;
– determination of ammonium chloride in licorice products.

Technical characteristics of the Behr D2 steam distillation unit:

– Frequency: 50/60 Hz
– Power: 1700 W
– Cooling fluid consumption: 5 l / min
– Display: LCD
– Programs: 1
– Dimensions (WxHxD): 41×67.5×41
– Weight: 32 Kg

  • Supplier in Bangladesh- Elite Scientific & Meditech Co
  • For any queries visit us- www.elitetradebd.com

#Distillation unit for determination of volatile acids #Steam distillation unit for determination of volatile acids #Behr D2 #Behr D2 distillation unit #Distillation unit #Steam distillation unit Behr D2 for the determination of volatile acids by distillation in a volumetric flask # Behr D2

Categories:  
Assalamu Alaikum, Welcome to our company
Scan the code