ICU ventilator, BT-S1600 

$0.00

Product description

BT-S1600 ICU Ventilator

Application:

The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Intra-operation,  post-operation respiratory support, other respiratory treatment.

Trust Points

l Simplicity: easy to use, easy to move with 4 wheels.

l Choice: adapt the equipment to your patients and procedures freely

l Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 5 modes: IPPV; A/C; SIMV; SPONT/CPAP; MANU.

l Designed and manufactured by Perlong Medical with over 23 years experience in this area.

l Flexible configurations to suit your needs.

l International standard and advanced technology suitable for wide range use.

l Compact interface and big screen give you better operating experience.

l Over 2,000 units installed in the world.

Features

l 10.4” TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform. 

l Recycle breathing pipe, ensure easy operating and keep tidy.

l Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

l Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.

l Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

l Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.

l Venturi effect technology ensure the machine working without air gas source.

Safety

l Three level alarming system, visual and sound alarm information.

l With lots of alarming, reminding and protection functions.

l Advanced power management control technology.

l With built-in backup power source, when outside power source goes off, back-up power source starts to work.

l Self-check before running, eliminate system mistake.

l Separate design of electric and gas, keep safety running of ventilator.

Specifications

Ventilation modes: IPPV; A/C; SIMV; SPONT/CPAP; MANU
Ventilator parameter ranges
Tidal volume(Vt) 0, 20 mL ~ 1500 mL
Frequence(Freq) 1bpm ~ 100 bpm
I/E 4:1~1:8
PEEP 0cmH2O ~ 20 cmH2O
Pressure triggering sensitivity(PTr) -20 cmH2O ~ 0 cmH2O(Based on PEEP)
SIGH 0(off)  1/100 ~ 5/100
Apnea Ventilation OFF,5 s ~ 60 s
Monitored Parameters
Frequence(Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2000 mL
MV

Airway pressure

0 L/min ~ 99 L/min

0cmH2O ~ 100cmH2O

Oxygen concentration 15 % ~ 100 %
Graphical display:
P-T(pressure – time)
F-T(flow – time)
Size

1.Wooden case packing size(main engine):L 560*W 560*H 615mm , GW:35KG ; NW:17KG

2.Wooden case packing size(trolley):L650*W690*H 520 mm , GW:38KG NW:18G

Alarm and protection

The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm <11.3±0.3V
No tidal volume No tidal volume within 6s
High oxygen concentration alarm

Low oxygen concentration alarm

19%-100%

18%-99%

High Airway  pressure alarm

Low Airway  pressure alarm

High Minute Volume alarm

Low Minute Volume alarm

Continuous Pressure alarm

20cmH2O-100cmH2O

0cmH2O-20cmH2O

1L/min-99L/min

0-20L/min

(PEEP+1.5kPa) over 16s

Suffocation warning 5s-60s no spontaneous ventilation
Working conditions
Gas source O2,
Pressure 280kPa-600kPa
Voltage -220V±22V
Power frequency 50Hz±1Hz
Input power 40VA
Categories:  

Fetal monitor, BT-PM9E

$0.00

7″ Fetal Monitor, BT-PM9E

Compact and lightweight design
7″ color TFT screen, folding 90 degrees
Built-in high dot matrix thermal printer with long life
A standard patient event marker and a clinical event marking button to mark clinical events separately.
Auto fetal movement are available.
Multi-crystals, wide beam forming, high sensitivity ultrasound transducer, low ultrasound power
AC or Li-ion battery
More than 12 hours data storage, which can be recalled and reprinted.
Technical Specifications
Fetal Heart Rate :Multi-crystal,pulsed doppler,high sensitive
Transducer Strengh :<5mW/cm2
Working frequency : 1.0MHz
Signal processing :special DSP system and mode recognization
Measurement range :50~210 bpm
Alarm Range:  High:   160    170    180    190 bpm
Low :   90    100    110    120 bpm
The largest audio output power :: 1.5W
TOCO
Measurement range :0~100units
Battery working time :2 hours(no printer working)
Speaker :1W
Power Supply: AC 220V±20%,50Hz  or 8.4V Li-battery
Power consumption: <20W
Working Environment Temperature:    10~40 ℃, RH: 10~80%

Transducer Acoustic Output     Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-ave rage intensity does not exceed 100mW/cm2

Dimension :295W×240D×73H×mm
Net weight :1.75kg
Standard: FHR, TOCO, FM
Optional: Twins,FAS(Fetal acoustic simulator)

Categories:  

Nebulizer machine, BT-NEB12

$0.00

Nebulizer machine, BT-NEB12
Max Pressure: 3.5-4.0 bar
Operation Pressure 0.9-1.2 bar
Free air flow: 14lpm
Motor work life: 5000 hours
Mode of Operation: Non-Stop
Medication Size: < 0.5-10um
Nebulizer Rate: >0.30ml/min
Sound level: <55dB(A)

Accessories
Medication Cup 1pc
Adult Mask 1pc
Child Mask 1pc
Mouthpiece 1pc
Fuse 2 pcs
Filter 2 pcs, PP material

Categories:  

Infant radiant warmer, BT-NR03S

$0.00

Product description

Infant Warmer, BT-NR03S

Updated Functions:
1.Aluminium Magnesium Alloy;2.RS232 connnector ;3.Two infusion inlet,Two drawer
4.8” LCD colorful touch screen;5.Carbon steel heater for more effectivity
6.Special design Inclined heater head is more convenience for X ray test
7.With oxygen supply system and LED phototherapy

Specification:
8.Microprocessor based servo controlled temperature system
9.Three modes of control: Pre-warm, manual and automatic
10.Set temperature and central skin temperature, peripheral temperaqture,
11.air temperature,APGAR timer,heating power display separately
12.8” LCD colorful touch screen
13.Carbon steel heater for more effectivity
14.Special design Inclined heater head is more convenience for X ray test
15.Digital skin temperature sensor, the data is accurate and stable
16.Alloyed bracket, fastness
17.Alarms functions for safety includes power failure, temperature deviation,
temperature probe failure, over temperature
18.Integral timer to record therapy time
19.Bigger mattress,
20.Skin temperature trend for 5min
21.Electric infant bed tilt angle is ± 12o
22.Transparent protector folded down,with two infusion seals
23.Convenient X-ray cassette tray under infant bed
24.Electric height adjusted suit for operation
With observe light, oxygen supply system and LED phototherapy

Optional functions:
Low pressure aspirator ,internal / external;infant resuscitator (T piece) ,Air and oxygen blender ,Gel mattress

Categories:  

Patient monitor, BT-PM9D

$0.00

Product description

15” Patient Monitor, BT-PM9D
1.13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
2. Efficient resistance to interference of defibrillator and electrosurgical cautery;
3. SPO2 can testing for 0.1% Weak;
4. RA-LL impedance Respiration;
5. Trend Coexist Display;
6. OxyCRG DyNamic View Display;
7. Bed to Bed view Display;
8. Networking capacity ;
9. Options of printing, IBP, VGA and EtCO2;
10. UP to 4 hours working capacity of built_in rechargeable battery;
11.15″ high resolution color TFT LCD display;
12. Large volume of tabular and graphic trends information storage and easy to recall;
13. Anti-ESU, anti- defibrillator;
14. Capture dynamic waveforms.

Technical specification
Specifications:
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 ch
Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV,  auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S After Defi.
ECG Signal Range: ±8 m V ( Vp-p )
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p),  Accuracy:±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,
TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available

RESPARATION

Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5  KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy : ±2 rpm
Apean Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution Pressure:1mmHg
Accuracy  Pressure  Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy : 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy : ±2bpm

TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy : ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant:<10 Sec.

IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy : ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec

tandard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder, VGA,Wall mount, Trolley, Central station

Categories:  

12 Channel ECG, BT-ECG12

$0.00

12 Channel ECG
BT-ECG12
Features:
1.12 channel ECG machine with interpretation
2.7″ color TFT LCD display
3.Simultaneous 12 leads acquisition and (Manual/Auto)
recording with high resolution thermal printer
4.Manual/Auto working modes
5.Use digital isolation technology and digital signal processing
6.Baseline stabilization inspection
7.Full alphanumeric silicon keyboard
8.Support U disk storage
9.Support USB (Optional)
Technical Specifications
Lead: Standard 12 leads
Acquisition: Simultaneous 12 leads
A/D Converter: 14bit
Sampling Rate: 1000Hz
Working Mode: Manual/Auto
Interference Filter: AC Filter and EMG Filter
CMMR: ≥100dB (with AC filter)
Input Circuit: Floating, protection circuit against defibrillator effect
Input Circuit Current: ≤0.1μA
Input Impedance: ≥50MΩ
Patient Current Leakage: <10μA
Calibrating Voltage: 1mV±2%
Skin Voltage Tolerance: ≥±500mV
Time Constant: ≥3.2s
Frequency Response: 0.05 Hz~250Hz
Noise Level: <15μVp-p
Sensitivity Threshold: ≤20μV
Signal Channel Interference: ≤0.5mm
Printer: Thermal printer
Paper: 215mmx20m, roll
Page Speed: 6.25, 12.5, 25, 50mm/s (±3%)
Sensitivity Printer: 10mm/mV (AUTO), 2.5, 5, 10, 20mm/mV
CPU: 32 bits
Safe Class: GB9706.1, Class I, Type CF
Power Supply: AC 220V (±10%), 50Hz±1Hz, Power ≤60VA
AC 85~265V, 50/60Hz
DC14.8V (2200mAh), rechargeable Li-ion battery
Dimension: 310mm×220mm×89mm
Weight:3kg (with battery)

Categories:  

Syringe Pump, BT-SP500

$0.00

Product description

Syringe Pump,remote control
BT-SP500

1. 4.3” color segment LCD screen, backlight display, can be used in various lighting conditions
2. Simultaneous display: Time, Battery indication, Injection state, Mode, Speed, Injection volume and time, Syringe size, Alarm sound, Block, Accuracy, Body weight, Drug dose and liquid amount
3. Speed, time, volume and drug amount can be adjusted via remote control, easier operation, save time of doctor and nurse
4. Advanced technology, based on Linux system, more safe and steady
5. Multi injection modes: Volume/Time/Body weight mode
6. Visible and audible alarms cover all abnormal conditions
Technical Specification
Injection Rate Range
50ml syringe : 0.1~999.9ml/h (step :0.1ml/h)
1000~1800ml/h (step : 1ml/h)
30ml syringe :0.1~900ml/h (step :0.1ml/h)
20ml syringe :0.1~600ml/h (step :0.1ml/h)
10ml syringe :0.1~300ml/h (step :0.1ml/h)
5ml syringe :0.1~150ml/h (step :0.1ml/h)
Purge Rate
50ml syringe: 1800ml/h  (Bolus rate:   1200ml/h)
30ml syringe:900ml/h    (Bolus rate:   600ml/h)
20ml syringe:600ml/h    (Bolus rate:    400ml/h)
10ml syringe:300ml/h    (Bolus rate:    200ml/h)
5 ml syringe:150ml/h    (Bolus rate:    100ml/h)

Mechanical Precision
Within±2%
Preset Volume Range
0.1~1999.9ml
Occlusion Alarm Threshold
High: 800mmHg±200mmHg (106.7kPa± 26.7kPa)
Medium: 500mmHg ± 100mmHg (66.7kPa± 13.3kPa)
Low: 300mmHg ± 100mmHg (40.7kPa± 13.3kPa)
KVO Rate
0.1~5ml/h (step: 0.1 ml/h)
Fuse
F1AL/250V
2 pcs (installed inside pump)
Power Supply
100~220V, 50Hz, Built in Rechargeable Li-ion battery, 11.1V, Capacity ≥2000mAh; by charging 10 hours, it can work at 5ml/h (GB 9706.27-2005 medium rate) for 4 hours
Environment Requirement:
Operation: a) Ambient temperature: +5℃~+40℃
b) Relative humidity: 20%~ 90%
c) Atmosphere Pressure: 86.0~106.0 (kPa)
Transportation & Storage: a) Ambient temperature: -30℃~+55℃
b) Relative humidity: ≤95%
c) Atmosphere Pressure: 50.1~106.0 (kPa)
Alarm
Near, Injection finished, Preset dose injection finished, Occlusion, Syringe off, Syringe dislocated, Low battery, AC power off
Safe Class
Class I Type BF
Size
282mm(L)×210mm(W)×148mm(H)
Weight
2.2Kg

Categories:  

Defi monitor, BT-9000C

$0.00

Product details-

Defi-monitor/monophasic
BT-9000C
ECG:
ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6
NIBP:
Method: automatic oscillation
Working mode: manual/automatic
Measur: adult: 10-250mmHg
Ement: pediatric: 10-200mmHg
Rabge: neonatal: 10-135mmHg
TEMP:
Measurement range: 20-45℃
SpO2:
Display: SpO2 value, pulse histongram, waveform, pulse
Pulse:
Pulse range: 0~300bpm  Pulse accuracy: ±2bpm

Defibrillator:
(1) Defibrillator type   Manual, Synchronized, Asynchronized,
(2) Out put waveform   Monophasic or Biphasic
(3) Energy accuracy   ∠+1%
(4)  Energy selection  0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)
(5) Charging time       Maximum 10 seconds to 360 Joules
(6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)

7”TFT display

Categories:  

Defi-monitor, BT-8000D or biphasic BT-8000D

$0.00

Product description

Defi-monitor/biphasic
BT-8000D
ECG:
ECG lead: Ⅰ,Ⅱ,Ⅲ, aVR, aVL, aVF, V1-V6
Protegtion: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.
ECG lead/cable: general lead/cable for adult, pediatric and neonatal patients
Defibrillator:
(1) Defibrillator type   Manual, Synchronized, Asynchronized,
(2) Out put waveform   Monophasic or Biphasic
(3) Energy accuracy   ∠+1%
(4)  Energy selection  0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal at a resistance of 50)
(5) Charging time       Maximum 8 seconds to 360 Joules
(6)  Standard Adult/Pediatric Paddles   Reusable extermal adult paddles(pediatric paddles integrated)

7”TFT display

Categories:  

Single-channel Syringe Pump, BT-FA313

$0.00

Product Details

Single-channel Syringe Pump
BT-FA313

Compatible syringe:10ml 20ml 30ml 50/60ml
Infusion rate:0.1-400ml/h,(50ml/60ml);0.1-200ml/h,(20ml/30ml);0.1-99.9ml/h,(10ml)
Purge rate/bolus rate/top infusion rate: 400ml/h;(50ml/60ml);200ml/h;(20ml/30ml); 99.9ml/h;(10ml)
Volume limit:0-999.9ml,Step by 0.1
Accuracy:±3%;
Infusion step by:0.1ml /h
Visible & audible alarms:Syringe dislocation,Occlusion ,Near empty,Pause overtime ,Low battery ,VTBI completion,Power cord falling off,Malfunction,Incorrect syringe type,Electrical circuit jam
Occlusion pressure: high:20ml、30ml、50ml/60ml Syringe Spec:90Kpa±30Kpa;10ml Syringe Spec:100Kpa±30Kpa
Occlusion pressure::20ml、30ml、50ml/60ml Syringe Spec:50Kpa±30Kpa;10ml Syringe Spec:70Kpa±30Kpa
KVO rate:0.1ml/h ±0.02 ml/h
Power:AC:100V-240V 50Hz/60Hz   DC:12V
Pause overtime alarm:1min50s—2min
Applied standards: ISO 13485 & CE Certified

Categories:  

Ventilator with air compressor, BT-S900B2

$0.00

Product description

Ventilator

Model: BT-S900B2

Introduction:

The BT-S900B2 ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

Physical specifications
Display  10.4” LCD Display
Mode: pneumatically powered and electrically controlled system
Working Mode: Closed; Semi-Closed; Semi-Open
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5  kPa
Respiratory Rate 1bpm~99 bpm
gas concentration output 21% ~ 100%  adjustable
Maximum Minute ventilation ≥18L / min, permissible deviation: ±20 %
Breathing Mode A/C, SIPPV、IPPV、SIMV、PSIMV、CPAP、PCV、PEEP、SIGN、SPONT, MANUAL
Ventilator compliance : ≤30 Ml/kPa
PEEP: 0~1.0KPa
Ptr: ,-1.0~1.0 kPa
IMV frequency: 1 ~ 12 times/min, permissible deviation: ±15%.
I/E Ratio: 4:1~1:4
Tidal Volume range 0~2000ml resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety  Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point and the permissible error is -10% or 15%.
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating upper alarm: 0.9 kPa ~ 5.4 kPa
lower: 0.5kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Air source requirement: Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it’s working normally.

Categories:  

Sleep therapy bipap system, BT-S9600

$0.00

Product description

BT-S9600 Sleep Therapy System

Application:

The Bipap System makes a good performance in sleep center, home and other departments. From high to low acuity, simple to complex cases, adult to geriatric patients, Perlong Medical Bipap System offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

Trust Points

l Simplicity: easy to use, easy to take with your package anywhere.

l Choice: adapt the equipment to your patients and procedures freely.

l Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 4 modes: CPAP; S; T; S/T.

l Designed and manufactured by Perlong Medical with over 23 years experience in this area.

l Flexible configurations to suit your needs.

l International standard and advanced technology suitable for wide range use.

l Compact interface and screen display give you better operating experience.

l Over 2,000 units installed in the world.

Features

l TFT LCD screen displays the Ventilation parameters and alarming information.

l Integration breathing circuit design, ensure easy operating and keep tidy.

l Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

l Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

l Optimized design and fine manufacture, cooperating sound absorption composite, unique super mute design.

l Unique shuttle knob design, easy to operate and use in house.

l No need to add water by stopping the machine, very easy to use.

Safety

l Three level alarming system, visual and sound alarm information.

l With lots of alarming, reminding and protection functions.

l Advanced power management control technology.

Specifications

Ventilation modes: CPAP,S,T,S/T
Frequency Adjusting range:3bpm-40bpm
Increment:1bpm
Inspiration time Adjusting range:0-3s
Increment:0.1s
IPAP Adjusting range:4cmH2O-25cmH2O
Increment:0.5cmH2O
EPAP Adjusting range:4cmH2O-20cmH2O
Increment:0.5cmH2O
CPAP Adjusting range:4cmH2O-20cmH2O
Increment:0.5cmH2O
Ramp time Adjusting range:0-60min
Increment:1min
Rise time Adjusting range:0.1s-0.5s
Increment:0.1s
Inspiration trigger Adjusting range: auto adjusting, 1-3
Increment:1
Expiration trigger Adjusting range: auto adjusting, 1-3
Increment:1
Flex Adjusting range:OFF, 1-3
Increment:1
Humidifier Adjusting range:0-5
Increment:1
Ppeak 0-30cmH2O
Graphical display:

Airway pressure histogram

Size

Carton packing size:L 285*W 350*H 290mm , GW:4.5KG ; NW:3.5KG

Alarm and protection

Low ventilation         0-15L/min
High airway pressure            20cmH2O-30cmH2O
High frequency 1bpm-99bpm
Low frequency 1bpm-60bpm
Suffocation warning 8s-12s no spontaneous ventilation
The maximum limited pressure <12.5 kPa
Pipe detached

Working conditions

Using conditions

             Pipe detached 16s
Environmental temperature 5℃-35℃
Relative humidity 15%-95%
Atmosphere pressure 830hPa-1060hPa
Storage conditions -20℃-+60℃
Relative humidity 15%-95%
Atmosphere pressure 500hPa-1060hPa
Categories:  

Dual-channel syringe pump, BT-FA323

$0.00

Product description

Dual-channel Syringe Pump
BT-FA323

Compatible syringe:10ml 20ml 30ml 50/60ml
Infusion rate:0.1-400ml/h,(50ml/60ml);0.1-200ml/h,(20ml/30ml);0.1-99.9ml/h,(10ml)
Purge rate/bolus rate/top infusion rate: 400ml/h;(50ml/60ml);200ml/h;(20ml/30ml); 99.9ml/h;(10ml)
Volume limit:0-999.9ml,Step by 0.1
Accuracy:±3%;
Infusion step by:0.1ml /h
Visible & audible alarms:Syringe dislocation,Occlusion ,Near empty,Pause overtime ,Low battery ,VTBI completion,Power cord falling off,Malfunction,Incorrect syringe type,Electrical circuit jam
Occlusion pressure: high:20ml、30ml、50ml/60ml Syringe Spec:90Kpa±30Kpa;10ml Syringe Spec:100Kpa±30Kpa
Occlusion pressure::20ml、30ml、50ml/60ml Syringe Spec:50Kpa±30Kpa;10ml Syringe Spec:70Kpa±30Kpa
KVO rate:0.1ml/h ±0.02 ml/h
Power:AC:100V-240V 50Hz/60Hz   DC:12V
Pause overtime alarm:1min50s—2min
Applied standards: ISO 13485 & CE Certified

Categories:  

Sleep therapy system, BT-S9700 

$0.00

Product description

BT-S9700 Sleep Therapy System

Application:

The Bipap System makes a good performance in sleep center, home and other departments. From high to low acuity, simple to complex cases, adult to geriatric patients, Perlong Medical Bipap System offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

Trust Points

l Simplicity: easy to use, easy to take with your package anywhere.

l Choice: adapt the equipment to your patients and procedures freely.

l Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 2 modes: CPAP; S.

l Designed and manufactured by Perlong Medical with over 23 years experience in this area.

l Flexible configurations to suit your needs.

l International standard and advanced technology suitable for wide range use.

l Compact interface and screen display give you better operating experience.

l Over 2,000 units installed in the world.

Features

l TFT LCD screen displays the Ventilation parameters and alarming information.

l Integration breathing circuit design, ensure easy operating and keep tidy.

l Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

l Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

l Optimized design and fine manufacture, cooperating sound absorption composite, unique super mute design.

l Unique shuttle knob design, easy to operate and use in house.

l No need to add water by stopping the machine, very easy to use.

Safety

l Three level alarming system, visual and sound alarm information.

l With lots of alarming, reminding and protection functions.

l Advanced power management control technology.

Specifications

Ventilation modes: CPAP,S
CPAP Adjusting range:4cmH2O-20cmH2O
Increment:0.5cmH2O
Ramp time Adjusting range:0-60min
Increment:1min
Flex Adjusting range:OFF;1-3
Increment:1
Humidifier Adjusting range:0-5
Increment:1
Ppeak 0-30cmH2O
Graphical display:

Airway pressure histogram

Size

Carton packing size:L 285*W 350*H 290mm , GW:4.5KG ; NW:3.5KG

Alarm and protection

High airway pressure     10cmH2O-20cmH2O
Suffocation warning      8s-12s no spontaneous ventilation
Pipe detached              Pipe detached 16s
Working conditions

Using conditions

Environmental temperature 5℃-35℃
Relative humidity 15%-95%
Atmosphere pressure 830hPa-1060hPa
Storage conditions -20℃-+60℃
Relative humidity 15%-95%
Atmosphere pressure 500hPa-1060hPa
Categories:  

Blood coagulation analyzer, BT-PUN2048B

$0.00

Product description

Blood Coagulation Analyzer

BT-PUN2048B 

Specifications

Number of Channels : 2
Reagent Storage : 4
Sample Preparation
Positions : 6, 3 with timer
Reagent Volume : 100μl
Stray : ≤1%
Inter channel Error : ≤3%
Linearity Error : ≤1%
Features
1.The blood coagulation analyzer has two independent detecting places. It can detect different items and different samples of the same item contemporary.
2. It is based on photoelectric principle and can put up items of PT, APTT, TT, FBG and active measurements of many cruor factors.
3. It has a device reagent-adding can be automatically detected by which you can use ordinary sucker to add the regent. For your convenience, the mixing device is vibratile so you do not need to beat it up.
4. It has an inner printer so you can conveniently print the detecting report.
5. There are advanced design of optic system and data processing software to eliminate the disturbances of high-fat-blood, icterus, hemolysis and chyle.
6 .It has many functions ,such as detection, set, inquiry and showing & saving test results.
7. It has convenient  timing up function.
8. It can delete the test results of the last day when it starts up for the first time next day.

Categories:  

ESR analyzer, BT-PUC2068A

$0.00

Product description

ESR Analyzer

BT-PUC2068A

Specifications

Number of test samples : 10 items at the same time
Max test speed : 20 samples/hour
Suited ESR tube: 1.6ml ESR tube(vacuum or normal)
Samples volume : 1.6 ml anticoagulant blood (blood 1.28ml+anticoagulant0.32ml), the height of the inputting tube 60 mm
Accuracy range of sample: 50mm~64mm
Read resolution : ±0.2mm(westergren method result±1mm)
Interval of reading :1 minute
Test time :The test time is 30 minutes, equivalents to 1 hour
Westergren method: The test time is 60 minutes, equivalents to 2 hours Westergren method
Display:128×240 LCD screen
Power: 12V(SELV) by external power supply

Main function 
1. The sample means: a randomized into the sample position, ready for testing;
2. The resulting output: display and print the sample number (serial number), Wilcoxon method test results and the whole process of ESR curve, detection time and temperature; when the detection time 60 minutes, it can automatically calculate, display and print the Katz index;
3. The instrument has a select temperature compensation. When you select this function, it can at room temperature 18 °C -30 °C ESR correction based on test results corrected to 18 °C, the table values;
4. The instrument can store no less than 150 samples of test results, including sample number (serial number ), ESR values and dynamic curve;
5. Power protection, power failure, automatically save the completed testing of the test results;
6. Preparation of built-in thermal printer apparatus
7. Operation interface: membrane keyboard;
8. Communication interface: RS-232 serial interface

Categories:  

Biochemistry analyzer, BT-PUS2018N

$0.00

Product description

Biochemistry analyzer

BT-PUS2018N

Screen:Colorful screen (240*128)

Wavelength Range:300-800nm
Measurement Range:-0.001~3.000Abs
Precision:±1nm  (Center), ±6nm (405-800nm)
Repeatability:≤0.6%
Cross-contamination:≤0.5%
Colorimetric Pool:Titanium alloy
Filter:Standard: 5 filters (Totally 9 filters can be installed)
100 inspect parameters, 200 inspect results saved

Categories:  

Biochemistry analyzer, BT-PUS2018G

$0.00

Product Description

Semi-automatic Biochemistry analyzer

BT-PUS2018G

Specification:

Screen:8” colorful touch screen
Wavelength Range:300-800nm
Measurement Range:-0.100-3.500Abs
Precision:±3nm  (340nm)
Repeatability:≤1.0%
Cross-contamination:≤1.0%
Colorimetric Pool:Titanium alloy
Filter:Standard: 7 filters (Totally 9 filters can be installed)
200 inspect parameters, 5000 inspect results saved

495*320*210mm/ N.G.: 10kg
Single &double-wavelength detections

Categories:  

Auto hematology analyzer, BT-XFA6000

$0.00

Product description

Auto Hematology Analyzer(3 D 22 Parameters)
BT-XFA6000 

Test Items: WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram
Background Count:WBC: ≤0.3×109/L? ?RBC: ≤0.03×1012/L? ?HGB: ≤1g/L? ?PLT: ≤10×109/L
1.The principle of this machine is electrical impedance (EI).
2.The machine is mainly used for the quantitative measurement of the blood in the 19 parameters and 3 histograms.
3.This machine use Screw transmission technology ,it ensures the testing result more accurate
4.It can save 20,000 test results and the data can be searched by date, ID, SN.
5.The size of LCD display is 10.4″.
6.It has a built-in thermal printer.
7.It has four interfaces:RS232 joint,USB,PS2,Parallel port.
8.It can set up and edit the parameters of male,female,children and newborn.

Categories:  

Bloodgas electrolyte analyzer, BT-PL2000

$0.00

Product description

Bloodgas Electrolyte Analyzer
BT-PL2000

Testing Items:pH, PCO2 , PO2, Na+, K+, Cl-, Ca2+
Counting Parameters:pH(TC), PCO2(TC), PO2 (TC), HCO3-, SBC, BE, BEecf, TCO2, SO2%, P50, A-aDO2, RI, TCa, nCa
Advanced Technology:solid state ISE’s (Ion selective electrode)
Storage and Transportation:At normal temperature
Display:8 inches colorful LCD touch screen
Sample volume:150 mL whole blood
Results Storage:5,000
Printer:Built-in thermal or other connected one
Power Supply:110-240V wide range voltage
Working Situation:Temperature: 15-30degree, humidity: < 85%

Categories:  