Karl Fischer Titrator KFT-40C
Features:
* LCD display screen.
* Support KF Titration Mode and Titer Detection Mode.
* Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
* Selectable units including mg, mg/ L,%,ppm, etc.
* Settable parameters, including measurement unit, polarization current, stirring rate, titration rate stop volume, endpoint potential, stop criterion and etc.
* Store up to 200 titration data sets (GLP-compliant).
* Data can be easily transferred to printer via RS-232 communication interface.
* Reset feature automatically resumes all settings back to factory default options.
Technical Parameters:
Model | KFT-40C | |
Volumetric Titration | Range | 0.1mg~250mg |
Resolution | 0.1mg | |
Polarization Current Accuracy | 1μA±0.2μA;50μA±10μA | |
Repeatability | ±0.5% | |
GeneralParameters | Power Supply | 110~220V, 50/60Hz |
External Size(mm) | 340*400*400 | |
Packing Size (mm) | 540*490*480 | |
Net/Gross Weight (kg) | 10/12 |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Automatic Milk Analyzer, BIOBASE, China
Description
Introduction:
Features:
Specification:
Test item | Detection range | Accuracy |
Fat | 0.01—45% | ±0.06% |
Non-fat milk solids | 3%—40% | ±0.06% |
density | 1000—1160kg/m3 | ±0.3kg/m3 |
protein | 2%—15% | ±0.1% |
lactose | 0.01%—20 % | ±0.08% |
Water content | 0%—70% | ±3 % |
Sample temperature | 5℃—40℃ | ±1℃ |
freezing point | –0.4℃—–0.7℃ | ±0.001℃ |
Ash | 0.4 %—4 % | ±0.03% |
Images are reference only. Actual product may be different.
Click Our Social Network Links
DBT-127 Blaine Air Permeability Apparatus
Description
Blaine Air Permeability Apparatus DBT-127
Manual Cement Blaine Air Permeability Apparatus DBT-127
AS PER IS: 4031, 5516, 1727 and 4828, ASTM C-204, BS: 4359 Part II.
The apparatus is used for determining the Fineness of Cement in terms of specific surface expressed as total surface area in square centimeters per gram of cement. The Blaine apparatus draws a defined volume of air through a prepared bed of cement of defined porosity.
This is a variable flow type air permeameter.
Technical Parameters
Air cylinder inner lumen diameter: 12.7+-0.05mm
Air cylinder inner lumen Sample height: 15+-0.5mmm
Perforated plate hole number: 35PC
Perforated plate hole diameter: 1.0mm
Perforated plate thickness: 1-0.10mm
Voltage: 220V 50HZ
Images are reference only. Actual product may be different.
Click Our Social Network Links
Automated Liquid Handler, BK-ASP96
Features
Technical Parameters
Model | BK-ASP96 |
Plate Position | 4pcs |
Throughput | 96 |
Pipetting Principle | Replacement of air |
Pipetting Volume | 5-200ul |
Tips | 50ul, 200ul tips to choose |
Plate Specification | 96-well microplate, 96-well deep hole plate, PCR plate, 8-trip tube, suction tank, injection tank |
Function | Aspirate, dispense, blow, mix, dilute |
Display | 7-inch touch screen |
Power | 100W |
Power Supply | 100-240V, 50/60Hz |
External Size | 635*270*555mm |
Packing Size | 765*395*680mm |
Gross Weight | 33kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Automated Liquid Handler
High Temperature Test Chamber, XD236
Introduction:
XD236 is an intelligent automatic Western Blot instrument that delivers automated operation for Western blotting membrane strip experiment. XD236 Auto blot can satisfy Western blotting kits’ demands for experiment conditions, such as temperature, incubation time, liquid dispensing volume and so on.
Feature:
Technical Parameter:
Model | XD236 |
Test Strip Capacity | 1-36 or 1-30 strip |
Programming Capacity | ≥ 38+2 (fixed procedure) |
Number of Programmable Steps | 20 steps* 6 working phases |
Liquid Dispensation System | Standard 6-channel pumps liquid dispensing system |
Pump Dispensing Range / Increment | 250μl ~ 3000μl, 1μl increment |
Accuracy of The Pump Dispensing | ±3.0% (dispensing volume 2000μl ) |
Precision of The Pump Dispensing | CV ≤ 5.0% (dispensing volume 2000μl) |
Quantitative Correction | Quantitative correction |
Incubation Time / Increment | 0~24 hours / 1 min increment; can be recycled |
Incubation Time Display | Hours, minutes and seconds |
Shaking Speed | 3 gear optional |
Temperature Control of Shaker | Accuracy ± 1.5 ℃, Fluctuation ≤ 0.2 ℃ at 37 ℃;
Accuracy ± 1.5 ℃, Fluctuation ≤ 0.25 ℃ at 30 ℃ or 25 ℃ |
Display | Dot matrix LCD with backlight |
Communication | RS232 Interface, Baud 9600, Data bit 8, stop bit 1, parity check: NO |
Alarming | Alarms for reagents dispensing, waste overflow, work ending etc. |
Cleaning | Automatic rinsing when necessary |
Reagent Bottle Capacity | 200ml *5 |
Wash Bottle Capacity | 1000 ml* 1 |
Waste Bottle Capacity | 2000ml*1 (airtight negative-pressure liquid waste bottle) |
Cross Contamination | When negative and positive samples are tested in turn, the negative samples should not show positive bands |
Working Condition | Indoor use, altitude ≤ 3000m, 5~40 ℃, RH ≤ 80% at temperature < 31 ℃ |
Power Supply | 110~240V, 50/60Hz, 250VA |
External Size(W*D*H) | 630*500*400mm |
Packed Size(W*D*H) | 840*630*840mm |
Net weight | 33kg |
Gross weight | 70kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue High Temperature Test Chamber, XD236
Auto Blot System (Western Blot System)
Introduction:
XD236 is an intelligent automatic Western Blot instrument that delivers automated operation for Western blotting membrane strip experiment. XD236 Auto blot can satisfy Western blotting kits’ demands for experiment conditions, such as temperature, incubation time, liquid dispensing volume and so on.
Feature:
Technical Parameter:
Model | XD236 |
Test Strip Capacity | 1-36 or 1-30 strip |
Programming Capacity | ≥ 38+2 (fixed procedure) |
Number of Programmable Steps | 20 steps* 6 working phases |
Liquid Dispensation System | Standard 6-channel pumps liquid dispensing system |
Pump Dispensing Range / Increment | 250μl ~ 3000μl, 1μl increment |
Accuracy of The Pump Dispensing | ±3.0% (dispensing volume 2000μl ) |
Precision of The Pump Dispensing | CV ≤ 5.0% (dispensing volume 2000μl) |
Quantitative Correction | Quantitative correction |
Incubation Time / Increment | 0~24 hours / 1 min increment; can be recycled |
Incubation Time Display | Hours, minutes and seconds |
Shaking Speed | 3 gear optional |
Temperature Control of Shaker | Accuracy ± 1.5 ℃, Fluctuation ≤ 0.2 ℃ at 37 ℃;
Accuracy ± 1.5 ℃, Fluctuation ≤ 0.25 ℃ at 30 ℃ or 25 ℃ |
Display | Dot matrix LCD with backlight |
Communication | RS232 Interface, Baud 9600, Data bit 8, stop bit 1, parity check: NO |
Alarming | Alarms for reagents dispensing, waste overflow, work ending etc. |
Cleaning | Automatic rinsing when necessary |
Reagent Bottle Capacity | 200ml *5 |
Wash Bottle Capacity | 1000 ml* 1 |
Waste Bottle Capacity | 2000ml*1 (airtight negative-pressure liquid waste bottle) |
Cross Contamination | When negative and positive samples are tested in turn, the negative samples should not show positive bands |
Working Condition | Indoor use, altitude ≤ 3000m, 5~40 ℃, RH ≤ 80% at temperature < 31 ℃ |
Power Supply | 110~240V, 50/60Hz, 250VA |
External Size(W*D*H) | 630*500*400mm |
Packed Size(W*D*H) | 840*630*840mm |
Net weight | 33kg |
Gross weight | 70kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Auto Blot System (Western Blot System)
Gas Chromatograph, BK-GC900
Introduction:
BK-GC900 gas chromatograph is a popular, high-performance, multi-functional series of chromatographic instruments. FID, TCD and FPD detectors can be combined as needed to meet the needs of ordinary laboratories, daily production, routine detection and trace quantities analysis requirements. It can be widely used in many fields such as petroleum, chemical industry, environment, food safety, disease control, teaching and scientific research.
Features:
1.Ethernet communication interface is adopted, so that the instrument can realize long-distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data
2.The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of background noise, which can lead to lower detection limits.
3.Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.
4.The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling
5.The inlet can be installed up to 4 types (packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.
6.The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation.Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve
Technical Parameters
Model | BK-GC900 | |
Oven | Temp. Range | RT+5~450℃ |
Temp. Accuracy | ≤±0.1℃ | |
Temp. Program | 20-phase | |
Max. Temp. Heating Rate | 40℃/min | |
Time Range | 0-655min | |
Internal Size | 250*270*170mm | |
Detector | Hydrogen Flame Ionization Detector (FID) |
|
Temperature 450℃ | ||
Compatible with packed and capillary columns | ||
Baseline drift:≤2×10-13A/30min | ||
Baseline noise: 3×10-14A | ||
Linear range:≥107 | ||
Thermal Conductivity Detector (TCD) | Sensitivity: >5000mv.ml/mg
(50mg/ml toluene-benzene solution) |
|
Temperature 400℃ | ||
Baseline drift:≤0.1mV/30min | ||
Baseline noise: 0.03mV | ||
Linear range:≥105(±10%) | ||
Flame Photometric Detector (FPD) |
|
|
|
||
Temperature 350℃ | ||
Injection Method | Various injection methods are available:
1) Packed column injection; 2) Packed column gasification injection; 3) Capillary split/splitless injection: back pressure valve control technology, linear split; 4) Six-way valve gas injection; 5) On-line injection: continuous injection for 24 hours without supervision |
|
Power Supply | AC220V±10%, 50/60Hz | |
Standard Accessory | FID detector, Chromatography workstation software, Capillary sampler | |
Optional Accessory | Sample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converter | |
External Size(L*W*H) | 530*502*508mm | |
Net Weight | 42kg | |
Package Size (W*D*H) | 750*710*720mm | |
Gross Weight | 60kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Freezing Point Osmometer BK-FPO-V2
Introduction
The freezing point osmometer produced by our company with independent research and development is in accordance with Raoul freezing point theory, based on the solution freezing point declined value proportional to the solution molar concentration, using high sensitivity of temperature-sensing element, to measure the freezing point of different solutions, so as to derive the osmotic pressure molar concentration. This theory has been widely used for the test and research of osmotic pressure molar concentration in the fields such as pharmaceuticals, pharmaceutical analysis, biological and food therapy
Feature:
Technical Parameter:
Model | BK-FPO-V2 |
Measurement Range | 0~2000 mOsmol |
Sample Amount | 100μl |
Testing Duration | ≤3min |
Pre-Cooling Time | ≤3min |
Measurement Error | ≤1% |
Repeatability | ≤1% |
Linearity | ≤1% |
Built-in printer | |
Audit Trail | Optional |
Environment Temperature | 0~30℃ Recommended for 15~25℃ |
Relatively Humidity | ≤60% |
Power Supply | 220V,50/60Hz (Standard); 110V, 60Hz (Optional) |
External Size(W*D*H) | 225*275*345mm |
Packed Size(W*D*H) | 420*545*580m |
Net weight | 12kg |
Gross weight | 25kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Freezing Point Osmometer
Total Organic Carbon Analyzer, BK-TOC2000 & BK-TOC3000
Features:
• Equipped with signal management system to realize accurate online setting, real-time monitoring, self-testing and flow speed controlling, also ensures perfect device performance and experiment safety
• Low current system design highly ensures the safety of operators
• Temperature can be set according to different samples which ensures complete sample digestion
• The power of cooling module can be set according to sampling volume which improves drying performance, also prohibits wet gas damaging the NDIR detector.
• Automatic leakage checking system not only avoids mis-operations also improves device performance and operation safety.
• Flow rate controlling system avoids the influence of flow rate fluctuation which ensures more accurate data
• TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly improves device performance
Technical Parameters:
Model | BK-TOC2000 | BK-TOC3000 |
Method | Dry method | Wet Chemical Oxidation By UV |
Digestion Mode | High Temperature Combustion | / |
Detector | NDIR | |
Parameters | TC, TIC, TOC, NPOC | |
Gas Requirement | Oxygen ≥ 99.995% | Nitrogen ≥99 995% |
Measurement Range | 0~30000mg/l (ppm) | 0~10000mg/l (ppm) |
Detection Limit | 50µg/l (ppb) | 5µg/l (ppb) |
Operation Mode | PC software Controlled | |
Application | Liquid Sample | |
Repeatability | 3% | |
Maximum Salinity | 85g/l | |
Power Supply | AC 220V, 50/60Hz (Standard); AC 110V, 50Hz (Optional) | |
Consumption | 200W | |
External Size(L*W*H) | 460*430*450mm | 460*360*450mm |
Net Weight | 28kg | 25kg |
Package Size(L*W*H) | 820*570*680mm | 660*610*680 mm |
Gross Weight | 52kg | 45kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Air Volume Meter - BK-AVM-1/BK-AVM-1S
Description :
Air volume meter is widely used in HVAC, purification technology and other industries for sealing and pipe air volume, temperature, humidity measurement.
Features:
Notice: Do not measure corrosive gases, gases containing metal particles, and gases containing large particles and high concentration of dust.
Technical Parameters:
Model | BK-AVM-1 | BK-AVM-1S | |
Air Volume
|
Range | 150~3500m³/h | 50-2500m³/h |
Accuracy | ±5%(F•S) | ||
Resolution | 1 m³/h | ||
Temp measurement | Range | / | 0~60℃ |
Accuracy | / | ±0.5℃ | |
Resolution | / | 0.1℃ | |
Humidity measurement | Range | / | 0~100%RH |
Accuracy | / | ±0.1%RH | |
Resolution | / | 0.1%RH | |
Power Supply
|
DC | 7.4V/1800mA | |
AC | 220V±10% 50Hz±2Hz | ||
Storage | Up to 999 test results | Up to 5000 test results | |
Standard Printer | Bluetooth printer | ||
Operating Environment |
|
||
Storage Environment |
|
||
Air Flow Hood | Standard: 570*570mm, 830*830mm | ||
Package Size | 750*750*180mm | ||
Gross Weight | 10kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Air Volume Meter
Whiteness Colorimeter, BK-W3C
Introduction:
The instrument uses the integrating sphere to realize the measurement of spectral diffuse reflectance. The optical principle is to use the blue light emitted by the semiconductor light source to directly enter the integrating sphere. The spectrum reflected by the surface is converted into an electrical signal by the silicon photocell after passing through the condenser lens, light barrier, and color filter group; another silicon photocell receives the base signal in the sphere. The two electrical signals are respectively amplified and processed by a single-chip microcomputer to realize the system functions of automatic zero calibration, working whiteboard calibration, and sample testing. Users can easily use this instrument to test the whiteness of various samples.
Application:
Whiteness colorimeter is widely used in building materials (cement, silicate, talcum powder, kaolin), daily chemicals (cosmetics, detergents, washing powder), ceramics (building ceramics, daily ceramics), flour, salt industry, food, Beverage, textile, flax, fiber, chemical industry, plastics, metallurgy, ultrafine powder, papermaking, printing, measurement, commodity inspection, etc.
Feature:
Wide range of applications:
The instrument can perform reflective measurement on solid samples, powder samples, pasty samples, silk samples and other surfaces.
Good measurement performance:
The computer-aided design is adopted to make the spectral characteristics of the instrument measurement sensor conform to the CIE standard observer response curve, and can accurately obtain the XYZ tri-stimulus value.
Rich color system and chromaticity value:
The instrument provides a variety of color systems, whiteness values and reference color differences, etc.
High automation and multi-function:
The instrument can automatically collect and process data during operation, and the operation is simple and fast. The instrument also has a complete editing function, the user can input or modify the data and color difference target value of the standard whiteboard through the keyboard, and can choose the output mode arbitrarily.
Technical Parameter:
Model | BK-W3C |
Lighting/Observation Condition | 0/d Condition |
Observing Condition | Standard D65 luminous source |
Standard Observer | 10° field of view |
Measuring Aperture | φ 1 8 mm |
Specimen Size | Diameter >φ15mm, Thickness <40mm |
Indication Accuracy | x, y 0.0001, other 0.01 |
Stability |
|
Measurement Accuracy | (Whiteness) W<1.0 |
Measurement Repeatability | (Whiteness)ΔW<0.2 |
Apparent Color Parameters | Absolute value: CIE XYZ, Yxy, L*a*b*, L*C*H*, Hunter Lab;
Chromatic aberration: Yxy, L*a*b*, L*C*H*, HunterLab; Whiteness: CIE86 whiteness Wg and TW value, R457 whiteness Wr value, Hunter whiteness Wh value, GB5950 whiteness Wj value, Stensby whiteness Ws value, Stephansen whiteness Wp value |
Power Supply | 220V,50/60Hz (Standard); 110V, 60Hz (Optional) |
Working Temperature | 0~40°C |
External Size(W*D*H) | 300* 330*280 mm |
Net Weight | 4.8 kg |
Packed Size(W*D*H) | 400*400*400mm |
Gross weight | 9kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Whiteness Colorimeter
Hand-held Pesticide Residue Meter, BK-NY1D
Overview
This Handheld Pesticide Residue Test is portable, compact size and convenient to carry, adopts enzyme value method and shows the result of value. The pesticide residue is out of limits if 50% is positive, the higher of the value, the greater of the amount of residue.
Principle
This Pesticide Residue Rapid Test is based on cholinesterase hydrolyzing acetylcholine. Its hydrolysate impacts DTMB, forming the yellow coupling things. Organophosphate pesticide can control enzyme. The changes of absorption value can show the degree of controlled enzyme and then reflect the pesticide residue in samples.
Application
Detect products: agricultural and sideline products, daily food, seafood and its products and so on. Detect object: rapid quantitative testing of organophosphate and carbamate pesticide residues. Applicable units: departments of industry and commerce, hygiene, quality supervision, agriculture, trade and so on; trade markets, supermarkets, wholesale markets for agricultural products, hotels, large dining rooms, bases for agricultural production and so on.
Characteristics
Technical Parameters
Model | BK-NY1D |
Power Supply | Lithium battery inside |
Storage |
500 records (please upload the figure to epistatic machine when the saved figure will reach the upper limit, or the figure will lose, test after deleting the figure in host) |
Display | LCD 128*64mm |
Transmittance Accuracy | ±3% |
Transmittance Repeatability | ±2% |
Linear error | ±5% |
Button | Panasonic soft button |
PC Interface | USB |
Working Environment | Temperature: 0~40°C, humidity: 35~85% |
Packing Size | 600*400*440mm |
Gross Weight | 6.5kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Hand-held Pesticide Residue Meter
Automatic Sealer, BK-AF96
Introduction:
BK-AF96 Automatic Sealer is a full-automatic equipment for sealing PCR plate, deep well plate, micro-plate, etc. It is mainly used for sealed storage of heat-sensitive substances, which can effectively prevent sample loss and cross contamination.
Features:
Technical Parameters:
Model | BK-AF96 |
Positions | 1pc |
Method | Cold Seal |
Speed | <16s/plate |
Operating Mode | Manual plate change, automatic sealing |
Application | PCR plate, deep well plate and micro-plate conforming to SBS standard(Customizable) |
Control Mode | Buttons |
Interface | USB |
Consumption | 75W |
Power Supply | 100-240V,50/60Hz |
External Size(L*W*H) mm | 310*380*410 |
Package Size (L*W*H) mm | 454*382*464 |
Net Weight | 16.5kg |
Gross Weight | 20.5kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Automatic Sealer
Transdermal Diffusion Meter, BK-TP6
Applications
The unit can objectively reflect the speed and degree of penetration of drug preparations through the skin of living animals in the specified solvent, and scientifically screen effective drugs with transdermal absorption conditions. It is one of the internationally recognized standard detection methods for drug transdermal release.
Technical Parameters
Model | BK-TP6 |
Transdermal Cup | 6pcs |
Capacity of Cell | 15ml(standard) |
Temperature Control Range | 30-40℃ |
Temperature Control Precision | ±0.1℃ |
Stirring Speed Range | 100-800r/min |
Speed Precision | ± 5% |
Power Supply | Standard: 220V, 50/60Hz; optional: 110V, 50/60Hz |
Power | 360W |
Packing Size | 420*420*380mm |
Gross Weight | 12kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Transdermal Diffusion Meter
Automatic Chemiluminescence Gel Imaging System BK-ACG600 & BK-ACG900
Applications
Features:
Technical Parameters:
Model | BK-ACG600 | BK-ACG900 |
Camera Resolution | 6.0MP | 9.1MP |
Cooling Temperature | -65℃ | |
Photosensitive Efficiency | >75% | >79% |
Pixel Size | 4.54*4.54um | |
Exposure Time | 1ms-120min | |
Pixel Density | 16 Bits (0-65535) | |
OD | ≥4.8OD | |
Lens | Standard: F=0.95, 25mm; optional: F=0.8,25mm | |
UV Transmission | LED 312nm, optional 470nm transmitted blue light | |
White Light Reflection | LED reflection (cold light) | |
Filter | Standard 590nm, other optional | |
Shooting Area | 16×14cm | |
Timer Shut Down | 1-60min | |
Power Supply | Standard: 220V 50Hz, Optional: 110V 60Hz(internal transformer) | |
Packing Size | 490*515*845mm | |
Gross Weight | 40kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Automatic Chemiluminescence Gel Imaging System
Gas Chromatograph, BK-GC901
Introduction:
BK-GC901 gas chromatograph can realize full EPC electronic flow control, realize full computer control of the instrument, and can be equipped with a high-precision liquid automatic sampler. It can be widely used in many fields such as petroleum, chemical industry, environmental protection, food safety, disease control, education and scientific research, and can analyze the macro, micro and trace amounts of organic matter, inorganic matter and gas.
Features:
Color widescreen, unique design of touch keys
Leading structural design
Humanized software operating system
Technical Specification
Model | BK-GC901 | |
Oven | Temp. Range | RT+5~450℃ |
Temp. Accuracy | ≤±0.01℃ | |
Temp. Program | 16-phase | |
Max. Temp. Heating Rate | 40℃/min | |
Time Range | 0-999.9min | |
Detector | Hydrogen Flame Ionization Detector (FID) | Detection limit:≤5×10-12g/s
(100ng/ul n-hexadecane-isooctane solution) |
Temperature 450℃ | ||
Compatible with packed and capillary columns | ||
Baseline drift:≤2×10-13A/30min | ||
Baseline noise: 3×10-14A | ||
Linear range:≥107 | ||
Thermal Conductivity Detector (TCD) | Sensitivity: >5000mv.ml/mg
(50mg/ml toluene-benzene solution) |
|
Temperature 400℃ | ||
Baseline drift:≤0.1mV/30min | ||
Baseline noise: 0.03mV | ||
Linear range:≥105(±10%) | ||
Electron Capture Detector (ECD) | Detection limit:≤1×10-14g/ml
(Sample: n-hexadecane δ-666) |
|
Linear range: ≥104 | ||
Flame Photometric Detector (FPD) | Detection limit:≤5×10-12g/s(S of 10ng/uL methyl parathion-ethanol solution)
Detection limit:≤4×10-12g/s(P of 10ng/uL methyl parathion-ethanol solution) |
|
Linear range (S): ≥103
Linear range (P): ≥104 |
||
Temperature 350℃ | ||
Nitrogen and Phosphorus Detector (NPD) | Detection limit:≤1×10-12g/s (Azobenzene)
Detection limit:≤1×10-12g/s(Marla sulfur phosphorous) |
|
Linear range: ≥103 | ||
Injection Method | Capillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc. | |
Inlet | 1~4, up to 3 capillary column inlets | |
Injection Type | Packed column injection, capillary column injection. (Flow setting range: 0~1000ml/min) | |
Control Accuracy | Pressure: 0.01KPa; Flow: 0.01ml/min | |
Maximum Split Ratio | 1:999 | |
Pressure Sensor | Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa | |
Flow Sensors | Accuracy: < 5% of full scale; Repeatability: 0.5K Pa (full scale); Output offset (accuracy): ±5% | |
Sampling Valve | Can be equipped with multiple imported automatic control valves, which can run automatically in sequence | |
Power Supply | AC220V±10%, 50/60Hz | |
Standard Accessory | FID detector, Chromatography workstation software, Capillary sampler | |
Optional Accessory | Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column. | |
Package Size | (W*D*H) 750*710*720 mm | |
Gross Weight | 70kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Ion Chromatograph
Ion Chromatograph, BK-IC120
Introduction:
The ion chromatograph not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with four orders of magnitude difference. Intelligent maintenance function is added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.
Features:
Technical Parameter:
Model | BK-IC120 | ||
Ion Chromatographic Pump | Type | High-pressure and low-pulsetwo-piston tandem advection pump | |
Maximum Pressure | 35MPa (PEEK) | ||
Pressure Display Accuracy | ≤0.1MPa | ||
Flow Stability |
|
||
Allowable Deviation of Flow |
|
||
Flow Range | 0.001~9.999mL/min | ||
Pressure Pulse | ≤0.5% | ||
Flow Precision | ≤0.1% | ||
Flow Accuracy | ≤0.1% | ||
Numerical-control and Electromagnetic Sample Injector |
Maximum Pressure | 35MPa | |
Contact Material of the Rotor | PEEK | ||
Control Mode | By Stepper motor | ||
Power Supply | 24V (DC) | ||
Suppressor | Type | Self-Regenerating electrolytic micro-membrane suppressor | |
Maximum Pressure | 6.0MPa | ||
Dead Volume | <50μL | ||
Digital and Temperature-control Detection System | Conductivity Detector | Type | Temperature–control and bipolar conductivity detector |
Detection Mode | Bipolar conductivity detection | ||
Cell Volume | ≤0.8μL | ||
Detection Range | 0~45000μS/cm | ||
Detection Resolution | ≤0.0020nS/cm | ||
Output Voltage | -6000~+6000mV (adjustable) | ||
Electronic Noise | 0.02nS | ||
Baseline Noise | ≤0.001μS | ||
Baseline Drift | ≤0.01μS | ||
Operating Temperature Range | Room temperature +5 ℃, ~60 ℃±0.01℃ | ||
Controlling, Temperature Accuracy | ±0.01 ℃ | ||
Maximum, Pressure | 10.0MPa | ||
Linear Range | ≥103 | ||
Instrument, Linearity | ≥0.999 | ||
Quantitative, Repeatability | ≤0.5% | ||
Qualitative, Repeatability | ≤0.5% | ||
Minimum Detectable Concentration | Cl-≤0.0002ug/mL; Li+≤0.0002ug/mL | ||
Flow System | Plastic Flow Path | Made of PEEK materials | |
Six-way Valve | PEEK material, pressure 5000psi; Independent, automatic collecting and flow function. |
Power Supply | 220V 50/60Hz (Standard);110V 50/60Hz (Optional);150W |
External Size(L*W*H*) | 350*470*510(mm) |
Net Weight (KG) | 26 |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Ion Chromatograph
Ion Chromatograph, BK-IC100
Introduction:
The ion chromatograph not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with four orders of magnitude difference. Intelligent maintenance function is added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.
Feature:
Technical Parameter:
Model | BK-IC100 | |
IC Pump
|
Type | High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure | 35 MPa (PEEK) | |
Pressure Display Accuracy | ≤0.1MPa | |
Flow Stability |
|
|
Allowable Deviation of Flow |
|
|
Flow Range | 0.001~9.999mL/min | |
Pressure Pulse | ≤0.5% | |
Flow Precision | ≤0.1% | |
Flow Accuracy | ≤0.1% | |
Manual Sample Injector |
Maximum Pressure | 35MPa |
External Diameter of the Tube | 1/16″ | |
Contact Material of the Rotor | PEEK | |
Contact Material of Medium | PEEK/Ceramics | |
Column Heater
|
Operating Temperature Range | 20~60℃ (68~140℉) |
Controlling Temperature Accuracy | ±0.01℃ | |
Allowable Deviation of Column Heater’s Temperature | ±1℃ | |
Temperature Stability | ≤0.05℃/h | |
Conduction
Detection System
|
Type | Constant temperature; auto-range conductivity detector |
Cell Volume | ≤0.8μL | |
Detection Range | 0~35000μS/cm | |
Detection Resolution | ≤0.0020nS/cm | |
Output Voltage | -6000~+6000mv(adjustable) | |
Electronic Noise | 0.02nS | |
Baseline Noise | ≤0.001μS/cm | |
Baseline Drift | ≤0.02μS | |
Operating Temperature Range | Room temperature +5℃~60℃ (41 ~140℉) | |
Controlling Temperature Accuracy | ±0.01℃ | |
Temperature Compensation | 1.7 %/℃ | |
Maximum Pressure | 10.0MPa | |
Linear Range | ≥103 | |
Instrument Linearity | ≥0.999 | |
Quantitative Repeatability | ≤1.0% | |
Qualitative Repeatability | ≤0.5% | |
Minimum Detectable Concentration |
|
|
Flow System
|
Plastic Flow Path | Made of PEEK materials |
Six-way Valve | PEEK material, pressure 5000psi; Independent automatic collecting and flow function. | |
Suppressor | Type | Self-Regenerating electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0MPa | |
Dead Volume | <50μL | |
Power Supply | 220V 50/60Hz(Standard);110V 50/60Hz (Optional);150W | |
External Size(L*W*H*) | 325*400*500mm | |
Net Weight | 21kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Ion Chromatograph
Hypochlorous Acid Water Generator, BL-150
Application
Suitable for family, school, nursing home, maternity center, central kitchen, food processing, cold chain, public places, epidemic prevention, animal husbandry, agricultural planting and other fields of daily disinfection, sterilization, deodorization, purification, etc.
Features
Technical Parameters
Model | BL-150 |
Output Capacity | 150L/H |
Available Chlorine Concentration | 30ppm, 50ppm, 90ppm |
PH Value | 5.0-6.5 |
ORP | ≥600mV |
Residual Chloride Ion | <1000mg/L |
Power | 1100W |
Power Supply | 110/220V, 50/60Hz |
Product Size | 692*542*617mm |
Net Weight | 70kg |
Packing Size | 806*651*772mm |
Gross Weight | 85kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue Hypochlorous Acid Water Generator
Manual Tablet Press Machine, BK-TPM10
Applications
It is a small desktop manual and the lightest single-punch tablet press machine. The machine has good performance, light operation and easy movement, which is very suitable for laboratories, family clinics and schools. This machine can press various grain-like crystals or powdery materials with good fluidity into tablets. It is suitable for small batch production and scientific research experiment teaching in pharmaceutical, health care products, food, agriculture, chemical industry, electronic batteries, metallurgical ceramics and other industries.
Technical Parameters:
Model | BK-TPM10 |
Max Pressure (KN) | 15 |
Max Diameter of Tablet (mm) | 12 |
Max Depth of Fill(mm) | 12 |
Max Thickness of Tablet(mm) | 6 |
Production Capacity(pcs/h) | About 2000pcs(Depends on hand crank speed) |
Overall Size(mm) | 330*220*520 |
Net Weight(kg) | 21 |
Packing Size(mm) | 400*330*600 |
Gross Weight(kg) | 33 |
Images are reference only. Actual product may be different.