Elite Scientific and Meditech Co.
Fluke T6-600 Electrical Tester
Model: Fluke T6-600 Electrical Tester
Fluke T6-600 Electrical Tester field sense technology for ac voltage, current, and frequency measurement without making electrical contact to live voltage. The most important things about the Fluke T6-600 electrical tester that always provide an accurate measurement in any environment.
You can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.
Key features: Fluke T6-600 Electrical Tester
5 reasons the T6 belongs in your toolbelt
Product Highlights
Tips: FieldSense Technology
Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:
FieldSense measurement looks like this when properly grounded:
Specifications: Fluke T6-600 Electrical Tester
Measurement Specifications | ||||||
Function | Requires test leads | Range | Resolution | Accuracy[1] | ||
FieldSense ac voltage true-RMS |
No | 600 V | 1 V | ±(3% + 3 counts) 45 Hz – 66 Hz[2] [3] | ||
FieldSense ac current true-RMS |
No | 200.0 A | 0.1 A | ±(3% + 3 counts) 45 Hz – 66 Hz | ||
FieldSense frequency (Hz) |
No | 1 Hz | ±(1% + 2 counts)[3] | |||
Volts ac true-rms | Yes | 600 V | 1 V | ±(1.5% + 2 counts) 45 Hz – 66 Hz | ||
Volts dc | Yes | 600 V | 1 V | ±(1% + 2 counts) | ||
Resistance | Yes | 2000 Ω | 1 Ω | ±(1% + 2 counts) | ||
Safety | 600 V CAT III | |||||
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
||||||
General Specifications | ||||||
Calibration | 1-year calibration cycle | |||||
Dimensions | 61.1 x 259.3 x 43.8 mm | |||||
Jaw opening | 17.8 mm | |||||
Weight | 0.35 kg (0.78 lb) | |||||
Temperature | Operating | -10 °C to +50 °C (14 °F to 122 °F) | ||||
Storage | -30 °C to +60 °C (-22 °F to +140 °F) | |||||
Altitude | Operating | 2,000 m (6,562 feet) | ||||
Storage | 10,000 m (32,808 feet) | |||||
Relative Humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) | |||||
0% to 75%, 30°C to 40 °C (86 °F to 104 °F) | ||||||
0% to 45%, 40°C to 50 °C (104 °F to 122 °F) | ||||||
Battery Type and Life | 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense | |||||
Temperature coefficient | 0.1 x (specified accuracy) / °C for <18°C or >28 °C | |||||
(< 64.4 °F or > 82.4 °F) | ||||||
Safety | IEC/EN 61010-1: Pollution Degree 2 | |||||
Electromagnetic Environment | IEC/EN 61326-1: Portable | |||||
Includes: Fluke T6-600 Electrical Tester
Includes:
Others related Meter
OTHERS Social LINKS
Fluke 317 Clamp Meter
Fluke 317 Clamp Meter
Fluke 317 Clamp Meter the rugged, reliable & accurate Fluke Clamp Meter that you can depend on. Fluke 317 is intended in the middle of ergonomic concepts, shaped to fit your hand and to enter tight bad skin easily. The Fluke 317 moreover present AC/DC current measurements and has a cutting edge solution for profusion knocked out 40 A. In calculation to a compact package considering a mighty feature set, the Fluke 319 along with equipping as soon as In-rush current and Frequency functions for scrutiny motors, lighting, etc.
Fluke 317 Clamp Meters
The two models are economic, compact and offer a range of special features:
Specifications:
General specifications | ||
Digital display | 6000 count resolution | |
Low battery Indication | Displays a signal when the batteries are below their required voltage | |
Power source | Three AAA IEC LR03 batteries | |
Clamp opening size | 1.45 in (37 mm) | |
Jaw diameter | 1.45 in (37 mm) | |
Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in | |
(162.4 x 58.25 x 30.5 mm) | ||
Weight | Approximately 13.5 oz (384 g) (batteries included) | |
Auto range | Available in Ohms | |
Safety | CE | |
EN/IEC 61010-1 and IEC 61010-2-032 | ||
Measurement Category: 600V CAT III | ||
317 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600 A} | ||
2.5% ±5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
319 Electrical specifications | |||
Current AC | Range | 40.00 A, 600.0 A, 1000 A | |
Resolution | 0.01 A, 0.1 A, 1 A | ||
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | ||
2.5% ±8 digit (60-500 Hz) {40 A} | |||
1.5% ±5 digit (50-60 Hz) {600/1000 A} | |||
2.5% ±5 digit (60-500 Hz) {600/1000 A} | |||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | ||
AC response | rms | ||
Current DC | Range | 40.00 A, 600.0 A, 1000 A | |
Resolution | 0.01 A, 0.1 A, 1 A | ||
Accuracy | 1.6% ±6 digit (40 A) | ||
1.5% ±5 digit (600/1000 A) | |||
Voltage AC | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1.5% ±5 digit (20-500Hz) | ||
AC response | rms | ||
Voltage DC | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1% ±4 digit | ||
Resistance | Range | 400.0 Ω | |
4000 Ω | |||
Resolution | 0.1 Ω | ||
1 Ω | |||
Accuracy | 1% ±5 digit | ||
Continuity | ≤ 30 Ω | ||
Inrush | Integration time | 100 ms | |
Frequency | Range | 5.0 – 500.0 Hz | |
Accuracy | 0.5% ±5 digit | ||
Trigger Level | 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A | ||
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
|||
Environmental specifications | |||
Operating temperature | 14°F to 122°F (-10 °C to 50 °C) | ||
Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) | ||
Operating humidity | Non-condensing (< 50 °F) (< 10 °C) | ||
90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |||
75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |||
45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |||
(Without condensation) | |||
Operating altitude | 1 mile (2000 meters) above mean sea level | ||
Storage altitude | 7 miles (12,000 meters) above mean sea level | ||
IP Rating | IP40 | ||
Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis | ||
Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor | ||
EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m | ||
Temperature coefficients | 0.1x (specified accuracy)/ °C | ||
(<64 °F or > 82° F) | |||
(<18 °C or > 28 °C) | |||
Fluke 317 Clamp Meters Includes:
Fluke 317 Clamp Meters Accessories:
Others related Meter
OTHERS Social LINKS
Fluke 305 Clamp Meter
Fluke 305 Clamp Meter Compact & very Easy to use. The Fluke 305 come following all the rugged, obedient and accurate features you have to meet the expense of in trust, in a small, ergonomic design.
The futuristic body design offers a more compact tool to meet your needs. With features of AC current measurements happening to 999 A, a large 30 mm jaw commencement and CAT IV 300 V/CAT III 600 V safety rating, you obtain a light-to-use tool that handles your unknown electrical maintenance needs.
Fluke Clamp Meter the most advanced test & measurement tools.
Key features: Fluke 305 Clamp Meter
Specifications: Fluke 305 Clamp Meter
Technical Specifications | ||
AC current | Range | 999.9 |
Accuracy | 2% ±5 | |
AC voltage | Range | 400/600 |
Accuracy | 1.5% ±5 | |
DC voltage | Range | 400/600 |
Accuracy | 1.5% ±5 | |
DC mV range | – | |
Resistance | Range | 4000 Ω |
Accuracy | 1% ±5 | |
Continuity | ≤ 70 Ω | |
Backlight display | Yes | |
Data hold | Yes | |
Size | H x W x D (mm) | 208 x 58.5 x 28 |
Jaw size | 30 mm | |
Safety rating | CAT III 600 V | |
Temperature | 0 ~ 40 °C | |
Screen refresh rate | . | |
Test leads | TL75 | |
Battery | 2 AA batteries | |
Warranty | 2 years |
Includes: Fluke 305 Clamp Meter
Accessories: Fluke 305 Clamp Meter
Test leads (1)
Others related Meter
OTHERS Social LINKS
Clamp Meter Fluke 303
Fluke 303 Clamp Meter Compact. Easy to use. Fluke tested. The Fluke 303 comes with all the rugged, reliable and accurate features you have come to trust, in a small, ergonomic design.
The advanced body design offers a more compact tool to meet your needs. With features of AC current measurements taking place to 600 A, a large 30 mm jaw commencement and CAT IV 300 V/CAT III 600 V safety rating, you profit an easy-to-use tool that handles your unspecified electrical part needs.
Key features: Fluke 303 Clamp Meter
Specifications: Fluke 303 Clamp Meter
Technical Specifications | ||
AC current | Range | 600.0A |
Accuracy | 1.8% ±5 | |
AC voltage | Range | 400/600 |
Accuracy | 1.5% ±5 | |
DC voltage | Range | 400/600 |
Accuracy | 1.5% ±5 | |
DC mV range | – | |
Resistance | Range | 4000 Ω |
Accuracy | 1% ±5 | |
Continuity | ≤ 70 Ω | |
Backlight display | Yes | |
Data hold | Yes | |
Size | H x W x D (mm) | 208 x 58.5 x 28 |
Jaw size | 30 mm | |
Safety rating | CAT III 600 V | |
Temperature | 0 ~ 40 °C | |
Screen refresh rate | > 2 times / sec. | |
Test leads | TL75 | |
Battery | 2 AA batteries | |
Warranty | 2 years |
Includes: Fluke 303 Clamp Meter
Others related Meter
OTHERS Social LINKS
Fluke 376 True RMS AC/DC Clamp Meter
The Fluke 376 True-RMS Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians for the measurement in single phase and three phase conductors. This digital multimeter measures current, voltage, resistance, frequency, capacitance and so on without disturbance in a high electromagnetic field.
Find the cause of difficult problems.
The 376 FC clamp meter uses integrated low-pass filters to measure non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp meter also uses unique inertial measurement technology to filter the noise and capture the motor flowing motor just as the circuit protection shows.
Measure:
Work safely and conveniently.
The 376 clamp meter carries a CAT III 1000V, CAT IV 600V protection rating designed to give you the highest potential protection on a piece of test tools.
The included iFlex flexible current probe provides easy access to large conductors in tight spaces. Flexible investigation:
We offer Fluke 376 clamp meter atthe best price in BD. The most important thing that we provide free delivery of any place in Bangladesh.
Key features: Fluke 376 True RMS AC/DC Clamp Meter
Specifications: Fluke 376 True RMS AC/DC Clamp Meter
Electrical Specifications | ||||||||||
AC Current via Jaw | ||||||||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||||||||
Resolution | 0.1 A | |||||||||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|||||||||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
|||||||||
AC Current via Flexible Current Probe | ||||||||||
Range | 2500 A | |||||||||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||||||||
376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
|||||||||
Accuracy | 3% ±5 digits (5 – 500 Hz) | |||||||||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||||||||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |||||||
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |||||||
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |||||||
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |||||||
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||||||||
DC Current | ||||||||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
||||||||
Resolution | 0.1 A | |||||||||
Accuracy | 2% ± 5 digits | |||||||||
AC Voltage | ||||||||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||||||||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||||||||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||||||||
DC Voltage | ||||||||||
Range | 374 and 375 376 |
600.0 V 1000 V |
||||||||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||||||||
Accuracy | 1% ± 5 digits | |||||||||
mV dc | ||||||||||
Range | 375 and 376 | 500.0 mV | ||||||||
Resolution | 0.1 mV | |||||||||
Accuracy | 1% ± 5 digits | |||||||||
Frequency via Jaw | ||||||||||
Range | 375 and 376 | 5.0 – 500.0 Hz | ||||||||
Resolution | 0.1 Hz | |||||||||
Accuracy | 0.5% ± 5 digits | |||||||||
Trigger Level | 5 – 10 Hz, ≥10 A | |||||||||
10 – 100 Hz, ≥5 A | ||||||||||
100 – 500 Hz, ≥10 A | ||||||||||
Frequency via Flexible Current Probe | ||||||||||
Range | 375 and 376 | 5.0 – 500.0 Hz | ||||||||
Resolution | 0.1 Hz | |||||||||
Accuracy | 0.5% ± 5 digits | |||||||||
Trigger Level | 5 – 20 Hz, ≥ 25 A | |||||||||
20 – 100 Hz, ≥ 20 A | ||||||||||
100 – 500 Hz, ≥ 25 A | ||||||||||
Resistance | ||||||||||
Range | 374 375 and 376 |
6000 Ω 60 kΩ |
||||||||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
||||||||
375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
|||||||||
Accuracy | 1% ± 5 digits | |||||||||
Capacitance | ||||||||||
Range | 1000 μF | |||||||||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
|||||||||
Accuracy | 1% ± 4 digits | |||||||||
Mechanical Specifications | ||||||||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | |||||||||
Weight | 388 g | |||||||||
Jaw Opening | 34 mm | |||||||||
Flexible Current Probe Diameter | 7.5 mm | |||||||||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||||||||
Environmental Specifications | ||||||||||
Operating Temperature | 10°C – +50°C | |||||||||
Storage Temp | -40°C – +60°C | |||||||||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
|||||||||
Operating Altitude | 3000 meters | |||||||||
Storage Altitude | 12,000 meters | |||||||||
EMC | EN 61326-1:2006 | |||||||||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
|||||||||
Safety Specifications | ||||||||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
|||||||||
Agency Approvals | ||||||||||
Batteries | 2 AA, NEDA 15A, IEC LR6 | |||||||||
Includes: Fluke 376 True RMS AC/DC Clamp Meter
Others related Meter
OTHERS Social LINKS
Fluke 373 True-RMS AC Clamp Meter
Fluke 373 True-RMS AC Clamp Meter easily can measures resistance to 6000 Ω with continuity detection.
Fluke 373 True-RMS AC Clamp Meter is an earsplitting substitute for AC-unaccompanied current measurement situations. Featuring True RMS AC voltage and current measurements you can undertaking AC current to 600 A and AC voltage to 600V. The 373 along with events DC voltage to 600 V and resistance to 6000.
To make it even easier to use, the large, easy-to-right of admission backlit display provides greater than before visibility in dimly lit conditions.
And the 373 automatically sets the truthful measurement range based very about the voltage function along with in the middle of your to power going on, so you get your hands on not need to impinge on the switch even if taking a measurement. When you put it all together, you’ll locate the Fluke 373 offers anything you need, benefit a tiny more.
Fluke tools always provide an accurate result in any environment. The wide range of Fluke clamp meter like as Fluke 381, Fluke 375, Fluke 368 FC also provide the best result that you are looking for.
Key features: Fluke 373 True-RMS AC Clamp Meter
Specifications: Fluke 373 True-RMS AC Clamp Meter
Electrical Specifications | |
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (48 – 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 @ 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0 % ± 5 digits (48 – 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1 % ± 5 digits |
Resistance | |
Range | 600.0 Ω/6000 Ω |
Resolution | 0.1 Ω/1 Ω |
Accuracy | 1 % ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 – 100.0 μF / 1000 μF |
Resolution | 0.1 μF/1 μF |
Accuracy | 1.9 % ± 2 digits |
Mechanical Specifications | |
Size (L x W x H) | 232 mm x 85 mm x 45 mm |
Weight | 370 g |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temp | -40 °C to +60 °C |
Operating Humidity | Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
Agency Approvals | |
Batteries | 2 AA, NEDA 15A, IEC LR6 |
Includes: Fluke 373 True-RMS AC Clamp Meter
Accessories: Fluke 373 True-RMS AC Clamp Meter
Clips (3)
Lights (2)
Test leads (3)
Test probes (1)
Others related Meter
OTHERS Social LINKS
Fluke 381 Remote Display True RMS AC/DC Clamp Meter
Fluke 381 Remote Display True RMS AC/DC Clamp Meter comes with great accuracy and always provide the accurate result that you are looking for.
Now one engineer can reach jobs that would, on the other hand, require two people. Clamp the Fluke 381 coarsely a conductor, cut off the display and wander across the room to operate controls or remove protective equipment, all even if watching definite-grow archaic-fashioned readings.
The iFlex Flexible Current Probe (included) expands the measurement range to 2500 A AC though providing increased display adaptableness. With a cord that runs 6 feet, you can finally exploit out those tight spaces, awkward sized conductors and disorganized wires.
Fluke clamp meter always provides an accurate result that you are looking for. Keep it, save it and share it.
Key features: Fluke 381 Remote Display True RMS AC/DC Clamp Meter
Safety Conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV
Specifications: Fluke 381 Remote Display True RMS AC/DC Clamp Meter
Electrical Specifications | |||||||
AC Current via Jaw | |||||||
Range | 999.9 A | ||||||
Resolution | 0.1 A | ||||||
Accuracy | 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) |
||||||
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 |
||||||
AC Current via Flexible Current Probe | |||||||
Range | 999.9 A / 2500 A (45 Hz – 500 Hz) | ||||||
Resolution | 0.1 A / 1 A | ||||||
Accuracy | 3% ± 5 digits | ||||||
Crest Factor (50/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
||||||
Position Sensitivity | |||||||
Distance from Optimum | |||||||
i2500-10 Flex | i2500-18 Flex | Error | |||||
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ±0.5% | ||||
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ±1.0% | ||||
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ±2.0% | ||||
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range. | |||||||
DC Current | |||||||
Range | 999.9 A | ||||||
Resolution | 0.1 A | ||||||
Accuracy | 2% ± 5 digits | ||||||
AC Voltage | |||||||
Range | 600 V /1000 V | ||||||
Resolution | 0.1 V / 1 V | ||||||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | ||||||
DC Voltage | |||||||
Range | 600.0 V /1000 V | ||||||
Resolution | 0.1 V / 1 V | ||||||
Accuracy | 1% ± 5 digits | ||||||
Frequency – Via Jaw | |||||||
Range | 5.0 – 500.0 Hz | ||||||
Resolution | 0.1 Hz | ||||||
Accuracy | 0.5% ± 5 digits | ||||||
Trigger Level | 5 – 10 Hz, ≥ 10 A 10 – 100 Hz, ≥ 5 A 100 – 500 Hz, ≥ 10 A |
||||||
Frequency via Flexible Current Probe | |||||||
Range | 5.0 to 500.0 Hz | ||||||
Resolution | 0.1 Hz | ||||||
Accuracy | 0.5% ± 5 digits | ||||||
Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
||||||
Resistance | |||||||
Range | 600 Ω/6 kΩ/60 kΩ | ||||||
Resolution | 0.1 Ω/1 Ω/10 Ω | ||||||
Accuracy | 1% ± 5 digits | ||||||
Mechanical Specifications | |||||||
Size (L x W x H) | 277 x 88 x 43 mm (55 mm for remote unit) | ||||||
Weight | 350 g | ||||||
Jaw Opening | 34 mm | ||||||
Flexible Current Probe Diameter | 7.5 mm | ||||||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | ||||||
Environmental Specifications | |||||||
Operating Temperature | -10°C to +50°C | ||||||
Storage Temperature | -40°C to +60°C | ||||||
Operating Humidity | Non condensing (< 10°C) ≤ 90% RH (at 10°C to 30°C) ≤ 75% RH (at 30°C to 40°C) ≤ 45% RH (at 40°C to 50°C) (Without Condensation) |
||||||
Operating Altitude | 2,000 meters | ||||||
Storage Altitude | 12,000 meters | ||||||
EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCC ID: T68-F381 RSS-210 IC: 6627A-F381 |
||||||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | ||||||
Wireless Frequency | 2.4 GHz ISM Band 10 meter range | ||||||
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV. |
||||||
Double Insulation Clearance | Per IEC 61010-2-032 | ||||||
Double Insulation Creepage | Per IEC 61010-1 | ||||||
Agency Approvals | |||||||
Includes: Fluke 381 Remote Display True RMS AC/DC Clamp Meter
Accessories:Fluke 381 Remote Display True RMS AC/DC Clamp Meter
Cases (1)
Clips (3)
Lights (2)
Current probes (1)
Test leads (3)
Test probes (1)
Others related Meter
OTHERS Social LINKS
Fluke a3001 FC Wireless iFlex® AC Current Module
Fluke a3001 FC Wireless iFlex® AC Current Module can solve problems faster by seeing live measurements from multiple test points on a single screen. Using a3001 FC current modules, you can:
Key features of Fluke a3001 FC Wireless iFlex AC Current Module
Specifications
Specifications: Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ± 5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz/60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|
LCD w/backlight | 3½ digits | |
Log rate/interval | 1-sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHz ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, a concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C |
|
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years |
Includes:
Models: Fluke a3001 FC Wireless iFlex® AC Current Module Includes:
Accessories:
Accessories: Fluke a3001 FC Wireless iFlex® AC Current Module, Cases (1)
Others related Meter
OTHERS Social LINKS
Fluke 772 Milliamp Clamp Meter
Fluke 772 Milliamp Clamp Meter measures, sources, and simulates 4-20 mA signals for the testing system I/O or IPs
The Fluke 772 adds to the essential capabilities of the Fluke 771 to save lots of longer and expand its applications. With the 771, you will even be in a position to supply and simulate 4-20 mA signals for the testing system I/O; live 4-20 mA signals with in-circuit measurement; power a transmitter with the twenty-four V loop power supply, and mechanically ramp and step amendment the 4-20 mA output for remote testing.
You’ll be ready to check 4–20 mA signals 5 times quicker than with ancient DMMs, and while not breaking the loop. which means you’ll be able to troubleshoot a live device while not having to power down, which might prevent time, and assist you to avoid presumably missing one thing occurring within the method.
Specifications: Fluke 772 Milliamp Clamp Meter
Specifications | |||||||
Diameter of measurable conductor | 0.177” or 4.5 mm max | ||||||
Operating temperature | -10 to 50ºC | ||||||
Storage temperature | -25 to 60ºC | ||||||
Operating humidity | < 90% @ <30ºC, < 75% @ 30 to 55ºC | ||||||
Operating altitude | 0 to 2000 m | ||||||
IP rating | IP 40 | ||||||
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) | ||||||
Weight | 410 g, (14.4 oz) | ||||||
Vibration | Random 2 g, 5 to 500 Hz | ||||||
Shock | 1 meter drop test (except the jaw) | ||||||
EMI/RFI | Meets EN61326-1 | ||||||
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. | |||||||
Temperature coefficient | 0.01% ºC (< 18ºC or > 28ºC) |
||||||
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms | ||||||
Warranty | Three years for electronics One year for cable and clamp assembly |
||||||
Functional Specifications | |||||||
mA measurement (measured by clamp) |
Resolution / range | 0 to 20.99 mA | |||||
Accuracy | 0.2% + 5 counts | ||||||
Resolution / range | 21.0mA to 100.0 mA | ||||||
Accuracy | 1% + 5 counts | ||||||
mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA | |||||
Accuracy | 0.2% + 2 counts | ||||||
mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA | |||||
Accuracy | 0.2% + 2 counts | ||||||
mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA | |||||
Accuracy | 0.2% + 2 counts | ||||||
Includes:
Models: Fluke 772 Milliamp Clamp Meter Includes:
Others related Meter
OTHERS Social LINKS
Fluke 375 True RMS AC/DC Clamp Meter
Fluke 375 True RMS AC/DC Clamp Meter comes with the Three-year warranty. The most important things about the Fluke 375 clamp meter, that always provide an accurate result at any environment.
With True RMS AC voltage and current measurements, the Fluke 375 Clamp Meter will scan up to 600 V and 600 A in each AC and DC modes, and is capable of frequency activity up to five hundred cycles per second.
In addition, the 375 is compatible with the new iFlex versatile current probe (sold separately), that expands the activity vary to 2500 A AC.
Specifications: Fluke 375 True RMS AC/DC Clamp Meter
Electrical Specifications | |||||||||
AC Current via Jaw | |||||||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
|||||||
Resolution | 0.1 A | ||||||||
Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
||||||||
Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
||||||||
AC Current via Flexible Current Probe | |||||||||
Range | 2500 A | ||||||||
Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
|||||||
376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
||||||||
Accuracy | 3% ±5 digits (5 – 500 Hz) | ||||||||
Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
||||||||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | ||||||
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | ||||||
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | ||||||
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | ||||||
Measurement uncertainty assumes centralized primary conductor at the optimum position, no external electrical or magnetic field, and within operating temperature range. | |||||||||
DC Current | |||||||||
Range | 374 and 375 376 |
600.0 A 999.9 A |
|||||||
Resolution | 0.1 A | ||||||||
Accuracy | 2% ± 5 digits | ||||||||
AC Voltage | |||||||||
Range | 374 and 375 376 |
600.0 V 1000 V |
|||||||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
|||||||
Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | ||||||||
DC Voltage | |||||||||
Range | 374 and 375 376 |
600.0 V 1000 V |
|||||||
Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
|||||||
Accuracy | 1% ± 5 digits | ||||||||
mV dc | |||||||||
Range | 375 and 376 | 500.0 mV | |||||||
Resolution | 0.1 mV | ||||||||
Accuracy | 1% ± 5 digits | ||||||||
Frequency via Jaw | |||||||||
Range | 375 and 376 | 5.0 – 500.0 Hz | |||||||
Resolution | 0.1 Hz | ||||||||
Accuracy | 0.5% ± 5 digits | ||||||||
Trigger Level | 5 – 10 Hz, ≥10 A | ||||||||
10 – 100 Hz, ≥5 A | |||||||||
100 – 500 Hz, ≥10 A | |||||||||
Frequency via Flexible Current Probe | |||||||||
Range | 375 and 376 | 5.0 – 500.0 Hz | |||||||
Resolution | 0.1 Hz | ||||||||
Accuracy | 0.5% ± 5 digits | ||||||||
Trigger Level | 5 – 20 Hz, ≥ 25 A | ||||||||
20 – 100 Hz, ≥ 20 A | |||||||||
100 – 500 Hz, ≥ 25 A | |||||||||
Resistance | |||||||||
Range | 374 375 and 376 |
6000 Ω 60 kΩ |
|||||||
Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
|||||||
375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
||||||||
Accuracy | 1% ± 5 digits | ||||||||
Capacitance | |||||||||
Range | 1000 μF | ||||||||
Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
||||||||
Accuracy | 1% ± 4 digits | ||||||||
Mechanical Specifications | |||||||||
Size (L x W x H) | 246 mm x 83 m x 43 mm | ||||||||
Weight | 388 g | ||||||||
Jaw Opening | 34 mm | ||||||||
Flexible Current Probe Diameter | 7.5 mm | ||||||||
Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | ||||||||
Environmental Specifications | |||||||||
Operating Temperature | 10°C – +50°C | ||||||||
Storage Temp | -40°C – +60°C | ||||||||
Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
||||||||
Operating Altitude | 3000 meters | ||||||||
Storage Altitude | 12,000 meters | ||||||||
EMC | EN 61326-1:2006 | ||||||||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
||||||||
Safety Specifications | |||||||||
Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
||||||||
Agency Approvals | |||||||||
Batteries | 2 AA, NEDA 15A, IEC LR6 | ||||||||
Includes:
Models: Fluke 375 True RMS AC/DC Clamp Meter Includes:
Others related Meter
OTHERS Social LINKS