Climate chamber ICH

$0.00

Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior – whether heat or cold – is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.

  • 3 models
    • Climate chamber ICH 110/260/750 with temperature and humidity
    • Temperature range from – 10 °C to + 60 °C  – ICH 110L/260L/750L with light
    • Temperature range from 0 °C to + 60 °C – ICH 110C/260C/750C with CO2 control
    • Temperature range from 0 °C to + 60 °C – 3 model sizes (108 to 749 litres volume)
  • 1 model variant
  • TwinDISPLAY
  • Digitally controlled active humidification and dehumidification from 10 to 80 % rh
  • Double doors as standard
    • Prevention of contamination and drops or rises in temperature with an optimal view of the chamber load through wide-area interior glass doors

In the ICH L model, tests in accordance with ICH guidelines Q1B, option 2, can be performed, thanks to an illumination unit. Fluorescent lights with cold white light (daylight: light colour 865, 6,500 K) and UV radiation in the spectral range of 320 – 400 nm. Daylight and UV light comply with standard illuminant D65. Thanks to a combination of temperature, humidity and digital CO2 control, the climate chamber ICH C is optimally suited for building materials testing or applications in cell biology requiring temperatures below room temperature. The air jacket temperature control ensures that the working chamber is sealed off from the outside all round.

The advantages:

  • Rapid and precise temperature control
  • No evaporator-dependent drying out of samples
  • No icing over of the cooling unit
  • No dehumidification of the working chamber

With the help of our model selection, with dimensioned model sketches and extensive technical data for download, you will find the perfect climate chamber ICH for your needs. For work predominantly close to the ambient temperature, we recommend the extremely energy-saving Memmert constant climate chamber HPP with an innovative and eco-friendly Peltier heating and cooling system.

A Memmert climate chamber ICH offers unique advantages:

  • Intuitive and easy-to-use operating menu
  • Temperature and humidity ramps programmable via AtmoCONTROL software
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Peltier heating and cooling concept specifically adapted for a precise and homogenous temperature control
  • A wide range of options for programming and documentation using interfaces, integrated data logger and software AtmoCONTROL
  • 3 years guarantee worldwide
  • The temperature tests for all climate chambers are performed in accordance with DIN 12880:2007-05
  • Each climate chamber ICH is safety-tested
Categories:  

Cooled Storage Incubators

$0.00

Why optimise the performance of a cooled incubator unnecessarily for rapid changes in temperature? The IPS cooled storage incubator exactly meets the requirements of the food or cosmetics industry, medicine, pharmaceutics for storing samples at constant temperatures: absolute reliability, precision and durability, and particularly environmentally friendly at the same time. With its extensive range of appliances with Peltier elements for heating and cooling – such as the IPP Peltier-cooled incubator, the IPS cooled incubator for storing samples at constant temperatures, the HPP constant climate chamber and the Peltier-cooling unit for waterbaths – Memmert is a market leader in this technologically sophisticated segment.

  • Temperature range +14 °C to +45 °C
  • 2 model sizes (256 and 749 litres volume)
  • 1 model variant: Single DISPLAY
  • Double doors as standard
    • Prevention of contamination and drops in temperature, and at the same time an optimal view of the load through fully glazed interior doors
  • Fans integrated in the Peltier elements ensure rapid energy transport and optimal temperature distribution

Since our IPS temperature control storage chamber, designed specifically for storing samples, does not require a compressor, it saves valuable space in the laboratory, just like its brother, the IPP Peltier-cooled incubator with a chamber volume from 32 to 749 litres. For applications requiring rapid changes in temperature, the Memmert ICP compressor-cooled incubator is recommended.

A Memmert cooled storage incubator IPS offers unique advantages:

  • Intuitive and easy-to-use operating menu
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Heating concept specifically adapted for a precise and homogenous temperature control
  • A wide range of options for programming and documentation using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide
  • The temperature values of all storage chambers are measured according to DIN 12880: 2007-05
  • Each IPS cooled storage incubator is safety-tested
Categories:  

Sterilisers SN/SF/SNplus/SFplus

$0.00

Descriptions

Our sterilizer S complies with all relevant standards and regulations for medical products and guarantees reliable programme sequences, irrespective of the load and chamber volume. Especially due to the SetpointWAIT function the validation of a Memmert hot air steriliser is possible anytime. Combined with the user-ID function the optional process-controlled, electromagnetic door lock of appliances with model variant TwinDISPLAY is the icing on the cake in terms of safety in the laboratory.

  • Temperature range up to +250 °C
  • 8 model sizes (32 to 749 litres volume)
  • 2 model variants: SingleDISPLAY and TwinDISPLAY
  • Natural convection or forced air circulation N/F
  • Medical device class IIb according to European Medical Devices Directive 93/42/EEC

Disinfection of appliances and instruments is not sufficient in medicine and research. Only sterilisation provides sufficient protection. In the Memmert hot-air steriliser, the SetpointWAIT function ensures that the programme is only continued when the setpoint temperature has been reached. Precisely maintaining the sterilisation time and thus completely killing off even highly resistant microorganisms is therefore guaranteed at all times, irrespective of the sterilisation load and chamber volume. This feature can also be used with additional, freely positionable Pt100 temperature sensors. In this case, sterilisation only begins when the setpoint temperature has been reached at all measurement points – that is, in the load. For the special application of depyrogenisation, the hot-air steriliser S is absolutely ideal. All Memmert sterilisers are classified as class IIb medical device. The appliances may be used for sterilising medical material through dry heat at atmospheric pressure. They are also suited without restriction for the special application of depyrogenisation with hot air.

A Memmert hot air steriliser offers unique advantages:

  • Intuitive and easy-to-use operating menu
  • SetpointWAIT function ensures that the programme is only continued when the setpoint temperature is reached
  • Optional process-controlled, electromagnetic door lock (models with TwinDISPLAY)
  • User-ID function prevents manipulation
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Heating concept specifically adapted for a precise and homogenous temperature control
  • A wide range of options for programming and documentation using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide
  • The temperature values of all sterilisers are measured according to DIN 12880: 2007-05
  • Each steriliser is safety-tested
Categories:  

Cooled Vaccum Drying Oven 29L

$0.00

Description

– Fuzzy-supported multi-level controlling controller adapting its performance to the volume (local temperature sensing) for each thermoshelf
– Offers state-of-the-art control technology based on the performance class
– Digital 7-day programme timer with real time clock, precise minute setting, for one set value or start of ramp operation
– Integrated timer for tempering and pressure (vacum) profiles of up to 40 ramps, parameters time, pressure and temperature (setpoint dependent) individually adjustable for each segment from 1 min up to 99 hrs
– Multiple over-termperature protection capability
– USB interface for documentation

Specification

Capacity 29 Litre
Temp. Range 5 to 90°C
Interior Dimensions 385 x 305 x 250 mm
Unit Dimensions 550 x 600 x 650 mm
Unit Weight 68 kg

 

Categories:  

Incubator IF30 Singledisplay 32L 30°C – 80°C

$0.00

Description

In the laboratory, Memmert incubators are ideal for all applications with temperatures up to +80°C specifically for incubating living cultures at +37 °C.
Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully.

  • Temperature range up to +80 °C
  • 8 model sizes 30 to 750
  • 2 model variants: SingleDISPLAY and TwinDISPLAY
  • Forced air circulation -F Double doors (interior glass, exterior stainless steel) for a clear view without a drop in temperature Activation of sterilisation routine via ControlCOCKPI

Memmert Incubator – A gentle force in the Laboratory

To guarantee optimum air circulation in the incubator chamber even when it is fully loaded, both model variants SingleDISPLAY and TwinDISPLAY are available with an adjustable air fan.

Since Memmert’s unique all-round surface heating is optimally geared to both natural convection and forced air circulation, the fan can be switched off entirely for sensitive samples and for samples which may not be exposed to air turbulence.

Specific use in Accordance with the German MPG (Law on medical devices) In accordance with the German Law on Medical Products (Directive 93/42/EEC), the incubators IN/ IF and INplus /IFplus can be used for the warming of irrigation solutions and infusions.

In accordance with the German Law on Medical Products (Directive 93/42/EEC), the incubators IN/ IF and INplus /IFplus can be used for the warming of irrigation solutions and infusions. 65 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our incubators: Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load A wide range of options for programming and documentation using interfaces, integrated data logger and AtmoCONTROL software

Three-year guarantee for appliances except wear and tear parts The temperature values of all incubators are measured according to DIN 12880: 2007-05 Each incubator is safety-tested and bears the CE mark

 

Categories: