Low Range EC & TDS,Portable pH/EC/TDS/Temperature Meter

$0.00

Features:

  • Automatic one or two point calibration
  • Multi-level LCD display; The meters display the current measurement simultaneously with the current temperature.
  • On-screen tutorial messages for calibration and setup
  • HOLD; The HOLD button freezes readings on the display for manual recording
  • Automatic Temperature Compensation
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Measure pH, EC/TDS and temperature with one probe
  • Battery % displayed on startup
  • Easy to clean and keep clean

HI 991301 has been designed to offer you  pH, conductivity, total dissolved solids and temperature measurements all in a slim, lightweight, portable unit. From purified to brine water measurement, you can select the meter which will work best with your range of conductivity for greater precision.

There are only 2 buttons, yet you can select from a range of calibration buffers and even the temperature scale (°C or °F) most familiar to you. The housing is waterproof and rated for IP 67 conditions.

The HI 1288 pre-amplified multiparameter probe features an easy to clean sensor and a cloth junction that can be pulled longer to increase the life of the probe. To ensure against interference from transient electrical noise, a solid-state amplifier is integrated into the HI 1288.

User selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (β) from 0.0 to 2.4% for greater consistency and reproducibility. Standardized buffer recognition values are also selectable.

This instrument easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in your way. The large, multi-level LCD displays the primary reading, temperature and calibration guides simultaneously.

Specifications:
Range pH 0.00 to 14.00 pH
EC 0.00 to 20.00 mS/cm
TDS 0.00 to 10.00 ppt (g/L)
Temperature 0.0 to 60.0°C (32.0 to 140.0°F)
Resolution pH 0.01 pH
EC 0.01 mS/cm
TDS 0.01 ppt
Temperature 0.1°C (0.1°F)
Accuracy pH ±0.01 pH
EC ±2% F.S.
TDS ±2% F.S.
Temperature ±0.5°C (±1.0°F)
TDS Conversion Factor  selectable 0.45 to 1.00 with 0.01 increments (default 0.50)
pH Calibration  automatic, one or two point calibration with two sets of memorized buffers (Standard 4.01, 7.01, 10.01 or NIST 4.01, 6.86, 9.18)
EC/TDS Calibration  automatic, 1 point at 6.44 ppt (CONV 0.5)
at 9.02 ppt (CONV 0.7)
at 12880 µS/cm (others)
Temperature Compensation pH Automatic
EC/TDS Automatic with selectable ß from 0.0 to 2.4%/°C with 0.1 increments
Probe  HI 1288 PVC body, pre-amplified multiparameter probe with internal temperature sensor, DIN connector and 1.2 m (3.93’) cable (included)
Battery Type / Life  1.5V AAA (3) /approximately 500 hours of continuous use. auto-off after 8 minutes of inactivity
Environment  0 to 50°C (32 to 122°F); RH max 100%
Dimensions  152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight  205 g (7.2 oz.)

Portable pH/EC/TDS/Temperature Meter, HI 991301 Hanna, Romania

$0.00

Product Features

  • Automatic one or two point calibration;
  • Multi-level LCD display: the meters display the current measurement simultaneously with the current temperature;
  • On-screen tutorial messages for calibration and setup;
  • HOLD: the HOLD button freezes readings on the display for manual recording;
  • Automatic Temperature Compensation;
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings;
  • Measure pH, EC/TDS and temperature with one probe;
  • Battery % displayed on startup;
  • Easy to clean and keep clean.

HI 991301 has been designed to offer you pH, conductivity, total dissolved solids and temperature measurements all in a slim, lightweight, portable unit. From purified to brine water measurement, you can select the meter which will work best with your range of conductivity for greater precision.

There are only two buttons, yet you can select from a range of calibration buffers and even the temperature scale (°C or °F) most familiar to you. The housing is waterproof and rated for IP67 conditions.

The HI 1288 pre-amplified multi-parameter probe features an easy to clean sensor and a cloth junction that can be pulled longer to increase the life of the probe. To ensure against interference from transient electrical noise, a solid-state amplifier is integrated into the HI 1288.

User selectable features include different TDS factors from 0.45 to 1.00 and a range of temperature coefficients (β) from 0.0 to 2.4% for greater consistency and reproducibility. Standardized buffer recognition values are also selectable.

This instrument easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesn’t get in your way. The large, multi-level LCD displays the primary reading, temperature and calibration guides simultaneously.

EC Meter, Hanna Romania

$0.00
Product Description:

HI 993310 is an instrument that has been specifically designed to address the question of correct and rapid measurement of conductivity in soil and liquids. It is supplied complete with two probes, HI 76305 with a stainless steel, conic tip for direct soil measurement, and HI 76304 for fertilizer enriched solutions.

HI 993310 measures both the soil conductivity in EC (mS/cm) as well as salt activity in grams per liter. The different scales can be selected through two keys on the front mask and two separate LED lights indicate which parameter is being tested. In addition, HI 993310 is equipped with an alarm LED that automatically turns on if the soil is too dry, or nutritive substances such as potassium or nitrogen are lacking. In the former case, de-mineralized water is to be added to the soil prior to proceeding with further tests. Direct soil measurement is facilitated by the small diameter, stainless steel, pointed HI 76305 probe. Once inserted into the ground, the user just needs to wait until the meter displays the value read by the auger-like probe.

Total hardness test kit

$2,500.00

Description-

Titration is used to find the concentration of an identified chemical in a solution (e.g., water).

In our standard Titration kits, there will be a Titrant solution that is added to the solution (e.g., water) to be tested to make it change colour. The Reagent is then added under monitored conditions.

Water Hardness Test Kit

The HI-3812 test kit tests the hardness level as mg/L (ppm) calcium carbonate, via an EDTA (ethylene-diamine-tetraacetic acid) titration. Range (0.0-30.0 mg/L) (0-300 mg/L).

During testing, when colour change is achieved, under careful conditions – usually using a burette – the reagent is added, drop by drop, until the solution turns to the colour required. The user will then count how many drops of reagent were used to achieve complete colour change. The number of drops used will determine the chemical concentration and results can be found in the manual included.

Water hardness has traditionally been defined as the capacity of water to precipitate soap. The ionic species in the water causing the precipitation was later found to be primarily calcium and magnesium. In the present, therefore, water hardness is actually a quantitative measure of these ions in the water sample. It is also now known that certain other ion species, such as iron, zinc and manganese, contribute to the overall water hardness. The measure and subsequent control of water hardness is essential to prevent scaling and clogging in water pipes.

Order Information:
HI 3812 test kit comes with 30 mL hardness buffer, 10 mL calmagite indicator, 120 mL EDTA solution, 20 mL plastic beaker with cap, 50 mL plastic beaker with cap and 1 mL syringe with tip

Specifications

Method Titration
Range 0.0-30.0 mg/L
0-300 mg/L
Smallest Increment 0.3 mg/L
3 mg/L
Chemical Method EDTA
Number of Tests 100
Weight 460 g

Hanna pH meter; Bench type, HI-2211

$0.00

Product Details

The HI2211 is a basic affordable pH/mV benchtop meter. Operation is simplified to calibration, mode selection (pH or mV), and a last stored reading feature. The HI2211 has a selection to choose between pH and mV modes. The mV mode is used with an optional ORP electrode that is used to check the oxidation or reduction potentials of a solution. Hanna offers a variety of ORP electrodes from glass to PEI plastic body styles. The mV mode of the HI2211 is also useful in checking the offset and slope of the pH electrode. Understanding the offset and slope characteristic is helpful in knowing if the probe is functioning correctly.

The HI2211 has a separate inputs for a BNC pH electrode and thermistor temperature probe. The BNC connector is a universal connector that is commonly available and allows the user to select from a wide variety of pH and ORP electrodes for their particular application. The separate temperature probe provides for a high 0.5°C accuracy measurement for precise temperature compensation

Specifications:
pH: Range: -2.00 to 16.00 pH
Accuracy: ±0.01 pH
Temperature: Range: -9.9 to 120.0°C
Accuracy: ±0.5°C from 0.0 to 100.0°C, ±1°C outside
mV (for #640-100-32 only): Range: ±399.9 mV; ±2000 mV
Accuracy: ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)

Features

• Displays pH (or mV with #640-100-32) and temperature simultaneously.
• Cat. #640-100-32 can also be used for ion concentration (ISE) and ORP.
• Easy calibration process with stability indictor makes the procedure error-free.
• Automatic temperature compensation.
• Supplied with a glass-body combination pH electrode with 1 m cable, temperature probe, electrode holder, pH 4 and 7 buffer solutions (20 ml each) and filling solution.
• Dimensions: 24 x 18.2 x 7.4 cm.
• Power: 120 volt, CSA Approved.
• Warranty: 2 years.

pH Meter; Bench top, HI-2211, Hanna

$0.00

Details

The HI2211 is a basic affordable pH/mV benchtop meter. Operation is simplified to calibration, mode selection (pH or mV), and a last stored reading feature. The HI2211 has a selection to choose between pH and mV modes. The mV mode is used with an optional ORP electrode that is used to check the oxidation or reduction potentials of a solution. Hanna offers a variety of ORP electrodes from glass to PEI plastic body styles. The mV mode of the HI2211 is also useful in checking the offset and slope of the pH electrode. Understanding the offset and slope characteristic is helpful in knowing if the probe is functioning correctly.

The HI2211 has a separate inputs for a BNC pH electrode and thermistor temperature probe. The BNC connector is a universal connector that is commonly available and allows the user to select from a wide variety of pH and ORP electrodes for their particular application. The separate temperature probe provides for a high 0.5°C accuracy measurement for precise temperature compensation

pH Specifications

pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy (@25ºC/77ºF) ±0.01 pH
pH Calibration automatic, one or two-point with five memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation automatic or manual from -9.9 to 120.0°C
mV Range ±399.9 mV ; ±2000 mV
mV Resolution 0.1 mV; 1 mV
mV Accuracy ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)

Temperature Specifications

Temperature Range -9.9 to 120.0°C (14.2 to 248.0°F)
Temperature Accuracy ±0.5 °C (0.0 – 100.0 °C); ±1 °C (outside)
Temperature Resolution
Categories:  