Nano Spectrophotometer with full spectrum covers a wide wavelength range of 190 to 850 nm. It requires only 0.3 – 2 �l sample for measurement which takes place within 5 seconds. It uses Xenon flash lamp as light source which has high stability and long operating life. It has built in Computer, screen & four USB interface. Nano spectrophotometer connected to mouse, printer, and other wireless card devices for multiple operations.
Features
Specification
Cuvette | Yes |
Temperature | 4 ºC – 42 ºC (Heating & Cooling) |
PC | Inbuilt |
Wavelength range | 190 – 850 nm |
Path length | 1 mm, 0.2 mm ,0.04 mm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Path length of cuvette | 1 mm/2 mm/5 mm/10 mm |
Minimum Sample size | 0.3 – 2.0 µl |
Absorbance range | 0 to 500 Abs |
Precision of wavelength | ± 1 nm |
Absorbance precision | 0.002 ~ 400 Abs (10 mm) |
Absorbance accuracy | 1 % (0.76 absorbance at 350 nm) |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Sample Pedestal Material | Stainless steel and quartz fiber |
Detector Type | 2048-element linear silicon CCD |
Screen | Color LCD Touchscreen display |
Software Compatibility | Win7 (64-bit operating system)/Win 8 |
Detects nucleic acid up to | 0.4 ~ 19000 ng/µL (dsDNA) |
Detects protein up to | 0.01 ~ 400 mg/mL (BSA) |
Dimension | 350 x 240 x 220 mm |
Weight | 5.2 kg |
Dispensing peristaltic pump LDPP-A10 is equipped with a touch screen controller that allows monitoring of parameters and change of speed. Equipped with a flow rate of 0.006 to 1600 mL/min and 0.006 ~ 2900 mL/min and advanced features such as flow rate calibration and anti-drip function. Four operational modes available for easy functioning. Intelligent cooling fan control helps in minimizing the work noise
Features
Specifications
Flow Range | 0.006 ~ 1600 mL/min |
Flow Accuracy | 0.2 %. |
Speed Range | 0.1 ~ 350 rpm |
No of channel | 1 |
Speed Resolution | 0.1 rpm |
Ambient Temperature | 0 ~ 40 °C |
Relative Humidity | < 80 % |
IP grade | IP 31 |
Power supply | AC 220 V ±10 % , 50 Hz / 60 Hz |
Power Consumption | < 40 W |
Dimensions ( L x W x H ) | 257 x 182 x 198 mm |
Weight | 5.3 kg |
Advanced Thermal Cycler (Basic) LATB-A10 is adopted with advanced peltier based semi-conductor technology for thermal uniformity, is used in multiple PCR based experiments. It uses 6 pieces of advanced (US) Marlow peltier with maximum cycle time more than 200,000. This thermal cycler works on latest Windows OS, performs control function, print function, stores large data through USB interface for reliable, safe usage.
Features
Specifications
Capacity | 96 × 0.2 ml |
Block Temperature Range | 0 to 99.9°C |
Temperature Control Accuracy | ≤ ± 0.2 ℃ |
Ramping Rate Adjustable | 0.1 to 2.5℃ |
Temperature Uniformity | ≤ ± 0.3 ℃ |
Heating Rate | 4 ℃/s |
Cooling Rate | 3 ℃/s |
Temperature Control Mode | Block \ Tube |
Hot-lid Temperature Range | 30 to 110℃ |
Hot Lid Height Adjustable | Stepless Adjustable |
Max No. of Steps | 9 |
Max No. of Cycles | 99 |
Time Increment/Decrement | 1 sec to 9 min 59 sec |
Temperature Increment/Decrement | 0.1 to 9.9℃ |
Program | 200 |
Pause Function | Yes |
Auto Data Protection | Yes |
Yes | |
LCD | 5.7 inch, 320 × 240 pixels |
Communication | USB 2.0 , RS232 |
Power Supply | 85 to 264 V AC , 47 to 63 Hz , 600 W |
Dimension ( L×W×H ) | 380 × 240 × 260 mm |
Weight | 10 kg |
Specific Gravity Tester LSGT-A10 determines the theoretical maximum specific gravity of bituminous mixtures in accordance to ASTM D2041 Standard Test Method for Theoretical Maximum Specific Gravity of Bituminous Mixtures (Vacuum process). Adopted with single chip machine technology to shake a loose asphalt mixture sample submerged in water. Vacuum is applied into the sample, to extract out the air bubble.
Features
Specifications
Vessel Volume | 4000 ml × 2 |
Power of Vacuum pump | 160 W |
Negative power | 3.7 kPa(27.75 mmHg) |
Power of shaking machine | 30 W |
Power supply | AC(220±10%)V, 50Hz |
Dimension | 510×520×380 mm |
LWT-A20 is designed according to ASTM D6304 “Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)” and ASTM D1744 standard to determine water content in the liquid petroleum products using Karl Fischer reagent. It is a multifunctional, convenient, and automatic analysis instrument.
Features
Specifications
Measurement Range | 1 μg ~ 100 mg (Representative value: 10 μg ~ 10 mg) |
Ambient Temperature | 5 °C ~ 40 °C |
Relative Humidity | ≤ 90 % |
Titration Speed | 2 mg / min |
Test Accuracy | 10 μg ~ 1 mg ± 3 μg |
Dimensions | 290 × 380 × 120 mm |
Power Consumption | 60 W |
Weight | 9 kg |
Power Supply | AC 220 V ± 10 %, 50 Hz ± 5 % |