Elite Scientific and Meditech Co.

elitetradebd@gmail.com

+8801711196910

elite, elitetrade, elitetradebd, elitescientific, elitebd, elitescientificbd, elitescientificco, elitescientificandmeditechco, elitescientificmeditechco, elitescientific&meditechco, elite scientific, elite scientific meditech co, elite scientific & meditech co, elite scientific and meditech co, scientific company in bangladesh, be scientific co, Bangladeshi scientific co, scientific products seller in Bangladesh, Scientific products seller in bd, scientific products supplier in bd, laboratory products selller in bd, lab goods seller in bd, Chemicals supplier in bd, Chemicals supplier in Bangladesh, glassware seller in bd, scientific goods price in bd, Tender goods seller in bd

2 ml amber glass HPLC vials for chemical storage

$30.00
2 ml HPLC Vials amber glass with black screw cap for chemical storage
  • Pack size: 100Pcs/Pkt
  • Origin: China

Descriptions

  • 2ml Amber glass hplc Flat Base vial automatic sampler vials 100Pcs/Pkt Product: of China
  • ALWSCI’s Autosampler vials, caps and Septa can be Compatible with kinds of autosamplers, including Agilent, Waters, Varian, Shimadzu, and etc.
  • 8-425 vials are uniformly flat bottom for security with inserts.
  • PTFE/Silicone Septa are most popular for HPLC applications
  • Pre-slit septa are casier to picrce with needles.
  • Pre-assembled caps and septa are convenient and minimize contamination form handling.
2ml 9-425 Vial
P/N Size Packing Description
2ML-8-VI001 12×32 100pcs/pk 2mL Amber Glass 12x32mm Flat Base 9-425 Screw Thread Vial with Label and ALWSCI Printing.

Supplier in Bangladesh Elite Trade BD, Elite Scientific & Meditech Co

Categories:  

8 ml Vials clear glass for chemical storage

$45.00
8 ml HPLC Vials clear glass with black screw cap
  • Pack size: 100Pcs/Pkt
  • Origin: China

Descriptions

  • ALWSCI Chemical Storage vials,also named sample vials, used in the package fo biological agent, cosmetics, high value chemistry and so on
  • Capacity range form 2ml to 60ml
  • Provide constant pH for Duration of sample storage life.
  • Chemically insert can be suitable for most chromatography and storage applications.
8ML-13VI00IC

P/N

Size Packing

Description

8ML-15VI00IC 17×60 100pcs/pk 8mL Clear Glass 17x60mm Flat Base Screw Thread Vial

Supplier in Bangladesh Elite Trade BD, Elite Scientific & Meditech Co

Categories:  

4 ml Vials clear glass for chemical storage

$35.00
4 ml HPLC Vials clear glass with black screw cap
  • Pack size: 100Pcs/Pkt
  • Origin: China

Descriptions

  • Chemical Storage Vials 4ml Glass Vials clear 100Pcs/Pkt Product: of China
  • ALWSCI Chemical Storage vials,also named sample vials, used in the package fo biological agent, cosmetics, high value chemistry and so on
  • Capacity range form 2ml to 60ml
  • Provide constant pH for Duration of sample storage life.
  • Chemically insert can be suitable for most chromatography and storage applications.

4ML-13VI00IC 

P/N Size  Packing

Description

4ML-13VI00IC 15×45 100pcs/pk 4mL Clear Glass 15x45mm Flat Base Screw Thread Vial

Supplier in Bangladesh Elite Trade BD, Elite Scientific & Meditech Co

Categories:  

2 ml Vials clear glass with black screw cap

$25.00
HPLC Vials 2ml clear glass
  • Pack size: 100Pcs/Pkt
  • Origin: China

Descriptions

  • 2ml clear glass hplc vial automatic sampler vials 100Pcs/Pkt Product: of China
  • ALWSCI’s Autosampler vials, caps and Septa can be Compatible with kinds of autosamplers, including Agilent, Waters, Varian, Shimadzu, and etc.
  • 8-425 vials are uniformly flat bottom for security with inserts.
  • PTFE/Silicone Septa are most popular for HPLC applications
  • Pre-slit septa are casier to picrce with needles.
  • Pre-assembled caps and septa are convenient and minimize contamination form handling.

2ml 9-425 Vial

P/N

Size Packing

Description

2ML-8-VI001 12×32 100pcs/pk 2mL Clear Glass 12x32mm Flat Base 9-425 Screw Thread Vial with Label and ALWSCI Printing.

Supplier in Bangladesh Elite Trade BD, Elite Scientific & Meditech Co

Categories:  

1.5ml Vials clear glass with black screw cap

$20.00
Vials 1.5ml Clear Glass with Screw Cap
  • Pack Size: 100Pcs/Pkt
  • Origin: China

Descriptions

  • 1.5ml clear glass hplc vial automatic sampler vials 100Pcs/Pkt
  • ALWSCI’s Autosampler vials, caps and Septa can be Compatible with kinds of autosamplers, including Agilent, Waters, Varian, Shimadzu, and etc.
  • 8-425 vials are uniformly flat bottom for security with inserts.
  • PTFE/Silicone Septa are most popular for HPLC applications
  • Pre-slit septa are casier to picrce with needles.
  • Pre-assembled caps and septa are convenient and minimize contamination form handling.
2ml 9-425 Vial
P/N Size Packing Description
2ML-8-VI001 12×32 100pcs/pk 2mL Clear Glass 12x32mm Flat Base 9-425 Screw Thread Vial with Label and ALWSCI Printing.

Supplier in Bangladesh Elite Trade BD, Elite Scientific & Meditech Co

Categories:  

Portable honey refractometer brix 58-90% for honey test ATC China

$2,500.00
ATC portable honey refractometer brix 58-90%

Description

ATC Portable Honey Refractometer Brix 58-90%

Specifications:

  • One SCALE Brix s: 58 to 90%Brix
  • Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)
  • Manual calibration with mini-screw driver provided

Package:

  • 1 x Refractometer
  • 1 x Pipette
  • 1 x Screw driver
  • 1 x Cleaning cloth
  • 1 x English Instruction manual

Supplier in BD: Elite Scientific & Meditech Co

Categories:  

Portable refractometer brix 28-62% sugar solution test

$2,500.00
ATC portable refractometer brix 28-62% for sugar test, China

Description

Portable Refractometer Brix 28-62% ATC, China

Brix Refractometer use to the sugar solution

Open daylight plate, and 2-3 drops of distilled water on the main prism, close the daylight plate so he q=water spreads across the entire surface of the prism without air bubbles or dry sport. Allow the sample to temperature adjust on the prisms for approximately 30 seconds before going to step 2. This allows the sample to adjust to the ambient temperature of the hand refractometer.

Hold daylight plates in the direction of the light source and look into the eyepiece. If you will a circular filed with Gradution down the entrance, you may have to focus the eyepiece to clear see the gradution. The uppers portion of the filed should be blue, while the lower portion should be white. The picture shown here and shown in stem 3 or 4 are only as reference.

Specifications:

  • One SCALE Brix s: 28 to 62%Brix
  • Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)
  • Manual calibration with mini-screw driver provided

Package:

  • 1 x Refractometer
  • 1 x Pipette
  • 1 x Screw driver
  • 1 x Cleaning cloth
  • 1 x English Instruction manual

Supplier in BD: Elite Scientific & Meditech Co

Categories:  

Salinity refractometer 0-100 ppm portable for salt test ATC China

$2,500.00
ATC Hand heal salinity refractometer 0-100ppm for salt test

Description

ATC Hand Heal Salinity Refractometer 0-100%

Salinity  Refractometer this meter used for All purpose  Nacl water solution

Open daylight plate, and 2-3 drops of distilled water on the main prism, close the daylight plate so he q=water spreads across the entire surface of the prism without air bubbles or dry sport. Allow the sample to temperature adjust on the prisms for approximately 30 seconds before going to step 2. This allows the sample to adjust to the ambient temperature of the hand refractometer.

Hold daylight plates in the direction of the light source and look into the eyepiece. If you will a circular filed with Gradution down the entrance, you may have to focus the eyepiece to clear see the gradution. The uppers portion of the filed should be blue, while the lower portion should be white. The picture shown here and shown in stem 3 or 4 are only as reference.

Specifications:

  • One SCALE Brix s: 0 to 100% Salinity Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)
  • Manual calibration with mini-screw driver provided

Package:

  • 1 x Refractometer
  • 1 x Pipette
  • 1 x Screw driver
  • 1 x Cleaning cloth
  • 1 x English Instruction manual

Supplier in BD: Elite Scientific & Meditech Co

Categories:  

Hand refractometer brix 0-90% for sugar test

$2,500.00
Hand refractometer 0-90% brix for sugar test, ATC, China

Description

Hand Refractometer Brix 0-90% ATC

Brix Refractometer use to the Heavy sugar solution

Open daylight plate, and 2-3 drops of distilled water on the main prism, close the daylight plate so he q=water spreads across the entire surface of the prism without air bubbles or dry sport. Allow the sample to temperature adjust on the prisms for approximately 30 seconds before going to step 2. This allows the sample to adjust to the ambient temperature of the hand refractometer.

Hold daylight plates in the direction of the light source and look into the eyepiece. If you will a circular filed with Gradution down the entrance, you may have to focus the eyepiece to clear see the gradution. The uppers portion of the filed should be blue, while the lower portion should be white. The picture shown here and shown in stem 3 or 4 are only as reference.

Specifications:

  • One SCALE Brix s: 0 to 90% Brix
  • Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)
  • Manual calibration with mini-screw driver provided

Package:

  • 1 x Refractometer
  • 1 x Pipette
  • 1 x Screw driver
  • 1 x Cleaning cloth
  • 1 x English Instruction manual

Supplier in BD: Elite Scientific & Meditech Co

Categories:  

Hand refractometer 0-32% brix for sugar test

$2,500.00
Automatic temperature compensation hand refractometer 0-32% brix

Description

Hand refractometer Brix 0-32% ATC

Brix Refractometer use to the sugar solution

Open daylight plate, and 2-3 drops of distilled water on the main prism, close the daylight plate so he q=water spreads across the entire surface of the prism without air bubbles or dry sport. Allow the sample to temperature adjust on the prisms for approximately 30 seconds before going to step 2. This allows the sample to adjust to the ambient temperature of the hand refractometer.

Hold daylight plates in the direction of the light source and look into the eyepiece. If you will a circular filed with Gradution down the entrance, you may have to focus the eyepiece to clear see the gradution. The uppers portion of the filed should be blue, while the lower portion should be white. The picture shown here and shown in stem 3 or 4 are only as reference.

Specifications:

  • One SCALE Brix s: 0 to 32%Brix
  • Reference Temperature: 20°C
  • ATC(Automatic Temperature Compensation) Compensation Range: 10°C~30°C (50°F~86°F)
  • Manual calibration with mini-screw driver provided

Package:

  • 1 x Refractometer
  • 1 x Pipette
  • 1 x Screw driver
  • 1 x Cleaning cloth
  • 1 x English Instruction manual

Supplier in BD: Elite Scientific & Meditech Co

Categories: