Bead beater-type homogenizer Beads crusher µT-12
0.00৳
Both swinging and powerful multi-sample & large-capacity at a reasonable price. High cost performance bead crusher !!
Main uses
● crushed animal cells or tissues
● crushing plant cell or tissue
● disruption of the bacterial cell
● crushed solids, such as tablets
Features
It crushes maultiple samples powerfully
The pendular swing method of max 3,200r/min crushes sample powerfully. Although the maximum speed is slower than µT-01, the swing amplitude is 1.5 times larger than conventional model giving the same power of crush. This mechanism raising the crush power with amplitude rather than speed is reducing the heating of samples by bead friction. If cool holder (TH-0203) or pre-chilled samples are used, it is possible to keep temperature below room temperature even after crushing. Please refer to below table for detail.
Pendular swing method
|
![]() |
Easy operation and silent operation
Operation is very easy; select shaking speed and set timer (1-300sec).
Since memory function is equipped, shaking speed and timer with high-frequency is possible to memorize.
In addition, it is very quiet compared with equivalent bead crushers.
Commercial tubes and materials for crushing are usable
Commercial tubes with 1.5/2.0 or 5ml screw cap are used for crushing. Stainless (SUS), zirconia and glass beads are usable. Stainless beads with φ2/3/4/5mm are available.
Loadable 5 ml micro tube
It can load two 5ml screw cap tube for mass processing which cannot be available in 1.5/2.0 ml tubes. For example, minimum 1g can be crushed for animal organs. Although the maximum shaking speed is up to 2500 r/min, it can provide enough power of crush since the amplitude is optimal.
Specifications
| Model | µT-12 |
| Shaking Method | Pendular swing method |
| Shaking Speed | 1800-3200 [r/min] 8 points |
| Surroundings temperature | +5-+35℃(*1) |
| Timer | Digital display 1 – 300 sec. countdown / (Minimum setting value 1 [sec.]) |
| Safety device / function | Limiter for open/close lid(Stop shaking when lid open), Overcurrent protection safety device |
| Applicable Container / Number | 1.5/2.0ml general screw cap micro tube x 12 pc when using 2 of TH-0206 holders(Option). 1.5ml general screw cap micro tube x 6 pc when using 2 of TH-0203 holders (Option). 5.0ml general screw cap tube x 2 pc when using 2 of TH-0501 holders (Option). |
| Dimensions | 310 x 400 x 200Hmm |
| Applied beads | All of nonmetallic beads, stainless beads and metal crusher |
| Weight | Approx. 15kg |
| Power Supply | AC100V 4A |
●The container on the Images are not standard accesorries.
Related products
-
Scientific and Surgical
Digital Desktop ultrasonic cleaner BULC-101, ESMC, Biolab, Canada
80,000.00৳ Add to cart -
Scientific and Surgical
L9/12/B510 Muffle Furnace, Tmax1200 with lift door, 9L, Nabertherm, Germany
0.00৳ Add to cart





