Fraction Collectors,Foxy® R1 & Foxy® R2 Multi-sample Automated

0.00৳ 

 Overview

The one-rack Foxy R1 fraction collector and the two-rack Foxy R2 fraction collector offer a range of capabilities and capacities to meet practically any need. All feature cold room friendly design and are built with moisture resistant materials. Ideal for applications such as HPLC collection, low-pressure biochromatography, protein and peptide purification
By choosing from the available racks the Foxy R1 or Foxy R2 can distribute fractions into 96 well microplates, standard tube or vial sizes, and bottles. For essentially unlimited volumes, funnel racks can direct fluids to any collection vessel or downstream process.
The Foxy R2 fraction collector uses radio frequency identification (RFID) to automatically detect collection racks, for easy setup. All the racks and funnels available include RFID tags

Features of the Foxy R1 and Foxy R2 Fraction Collectors:

  • Collect peaks of interest separately using any combination of slope, level, and time window reliably separates peaks by monitoring detector output, so you don’t have to expend glassware on no-interest effluent
  • Collect uniform fractions by time, drop count, or pumped volume
  • Stores up to 8 collection methods
  • Choice of available racks, the Foxy R1 takes 1, the Foxy R2 takes two, specified when ordering
  • Coldroom friendly design
  • Sturdy cast aluminum frame
  • Easy to use symbolic touch screen interface
  • Built-in Ethernet and RS-232 communication capabilities
  • Faster tube changes
  • µL delay volume between diverter valve and drop former
  • Standard flow rates up to 25 mL/minute for the Foxy R1, up to 125 mL/minute for the Foxy R2, with optional kits to increase or decrease the maximum
  • The Foxy R2 uses Radio Frequency Identification (RFID) technology to automatically detect the rack type without user intervention, to set collection patterns and vessel capacities
  • The Foxy R2 is available with a high flow rate (up to 1000 mL/min) diverter valve
Specifications
Model: Foxy R1 Foxy R2
Maximal flow rate standard: (mL/min) 25 125
Maximal flow rate optional kit: (mL/min) 25 Optional kit 25, optional high flow diverter valve 1000
Delay volume: Diverter valve located at drop former, delay volume compensation only required for length of tubing to the diverter valve Diverter valve located at drop former, delay volume compensation only required for length of tubing to the diverter valve
Peak detection: Slope and/or level sense, with or without time window Slope and/or level sense, with or without time window
Tube changes: At detected peaks, plus drop counts, time, or external pump counts At detected peaks, plus drop counts, time, or external pump counts
System control: Front panel control via touch screen LCD, or by direct communication with fraction collector via Ethernet and RS-232 serial communications. Front panel control via touch screen LCD, or by direct communication with fraction collector via Ethernet and RS-232 serial communications.
Inputs: Pump counter, external peak, inject, tube advance, analog peak voltage Pump counter, external peak, inject, tube advance, analog peak voltage
Outputs: Pump pause, tube change Pump pause, tube change
Power: (V/Hz) 100-117/50-60 100-117/50-60
Size: W×D×H (mm) 311×330×355 311×533×378
Weight with drip tray, no rack: (kg) 7.7 10.6