Elite Scientific & Meditech Co.
Fluke 317 Clamp Meter
Fluke 317 Clamp Meter
Fluke 317 Clamp Meter the rugged, reliable & accurate Fluke Clamp Meter that you can depend on. Fluke 317 is intended in the middle of ergonomic concepts, shaped to fit your hand and to enter tight bad skin easily. The Fluke 317 moreover present AC/DC current measurements and has a cutting edge solution for profusion knocked out 40 A. In calculation to a compact package considering a mighty feature set, the Fluke 319 along with equipping as soon as In-rush current and Frequency functions for scrutiny motors, lighting, etc.
Fluke 317 Clamp Meters
The two models are economic, compact and offer a range of special features:
Specifications:
General specifications | ||
Digital display | 6000 count resolution | |
Low battery Indication | Displays a signal when the batteries are below their required voltage | |
Power source | Three AAA IEC LR03 batteries | |
Clamp opening size | 1.45 in (37 mm) | |
Jaw diameter | 1.45 in (37 mm) | |
Dimensions (L x W x H) | 6.39 x 2.29 x 1.20 in | |
(162.4 x 58.25 x 30.5 mm) | ||
Weight | Approximately 13.5 oz (384 g) (batteries included) | |
Auto range | Available in Ohms | |
Safety | CE | |
EN/IEC 61010-1 and IEC 61010-2-032 | ||
Measurement Category: 600V CAT III | ||
317 Electrical specifications | ||
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | |
2.5% ±8 digit (60-500 Hz) {40 A} | ||
1.5% ±5 digit (50-60 Hz) {600 A} | ||
2.5% ±5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ±6 digit (40 A) | |
1.5% ±5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ±4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ±5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
319 Electrical specifications | |||
Current AC | Range | 40.00 A, 600.0 A, 1000 A | |
Resolution | 0.01 A, 0.1 A, 1 A | ||
Accuracy | 1.6% ±6 digit (50-60 Hz) {40 A} | ||
2.5% ±8 digit (60-500 Hz) {40 A} | |||
1.5% ±5 digit (50-60 Hz) {600/1000 A} | |||
2.5% ±5 digit (60-500 Hz) {600/1000 A} | |||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | ||
AC response | rms | ||
Current DC | Range | 40.00 A, 600.0 A, 1000 A | |
Resolution | 0.01 A, 0.1 A, 1 A | ||
Accuracy | 1.6% ±6 digit (40 A) | ||
1.5% ±5 digit (600/1000 A) | |||
Voltage AC | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1.5% ±5 digit (20-500Hz) | ||
AC response | rms | ||
Voltage DC | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1% ±4 digit | ||
Resistance | Range | 400.0 Ω | |
4000 Ω | |||
Resolution | 0.1 Ω | ||
1 Ω | |||
Accuracy | 1% ±5 digit | ||
Continuity | ≤ 30 Ω | ||
Inrush | Integration time | 100 ms | |
Frequency | Range | 5.0 – 500.0 Hz | |
Accuracy | 0.5% ±5 digit | ||
Trigger Level | 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A | ||
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C) Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C. True rms for ac V and ac A accuracy is specified from 5% to 100% of range. |
|||
Environmental specifications | |||
Operating temperature | 14°F to 122°F (-10 °C to 50 °C) | ||
Storage temperature | -40 °F to 140 °F (-40 °C to 60 °C) | ||
Operating humidity | Non-condensing (< 50 °F) (< 10 °C) | ||
90% RH (50 °F to 86 °F) (10 °C to 30 °C) | |||
75% RH (86 °F to 104 °F) (30 °C to 40 °C) | |||
45% RH (104 °F to 122 °F) (40 °C to 50 °C) | |||
(Without condensation) | |||
Operating altitude | 1 mile (2000 meters) above mean sea level | ||
Storage altitude | 7 miles (12,000 meters) above mean sea level | ||
IP Rating | IP40 | ||
Vibration requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis | ||
Drop test requirements | 3 ft (1 m) drop test, six sides, oak floor | ||
EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m | ||
Temperature coefficients | 0.1x (specified accuracy)/ °C | ||
(<64 °F or > 82° F) | |||
(<18 °C or > 28 °C) | |||
Fluke 317 Clamp Meters Includes:
Fluke 317 Clamp Meters Accessories:
Others related Meter