elitetradebd,elitescientific,elitescientific&meditech,elitescientific&meditechco,elitetrade,elite,elitescientificco,elitechemicalsco,elitewebsite,elitelabequipments,elitelaboratories,labgoods,bdscientific,scientificcoinbd

Spectrophotometer single beam, OPTIZEN POP-V

$0.00

OPTIZEN™ POP-V

THE SMART UV-VIS SPECTROPHOTOMETER

OPTIZEN POP-V are single-beam type spectrophotometers and offer stable performance and compact-size and reasonable price to the users.
The series are categorized into POP, POP-S, POP-V according to the specification of the products.

Main Characteristics

  • Checking and recording the temperature at the analysis moment by applying the temperature measurement system.
  • Offering ARM Cortex™ – A8 processor and supporting basic 16GB storage.
  • It can measure automatically lots of samples by using Multi Cell.
  • Supporting convenient voice service and volume control function.
  • Supporting network printer.

Specification

Photometrics System Single Beam Type
Light Source Tungsten Halogen Lamp
Spectral Bandwidth 3.0 nm (340 to 1100 nm)
Wavelength Range 340 to 1100 nm
Wavelength display 0.1 nm
Wavelength accuracy <± 1.5 nm
Wavelength repeatability <± 0.2 nm
Slew rate About 8,800 nm/min
Scan speed max 4,000 nm/min
Photometric range Absorbance : -3 to 3 Abs
Transmittance : 0 % to 300 %
Photometric accuracy ±0.005 (> 1.0 Abs)
Stray lighty < 0.05 % Nal at 220 nm, NaNO₂ at 340 nm
Baseline stability <± 0.002 Abs/h
Baseline flatness ± 0.003 Abs (340 to 1050 nm)
Monochromator Czerny-Turner type with 1200 lines/nm blazed grating
Lamp interchange Wavelength 340~410 nm (Default 370 nm)
Standard cell Holder Autometic Rotary type 8-position Multi-Cell Holder
Display 7 inch color LCD with touch screen;
Operating system(OS) Windows CE;
Power Requirement 100~240 V; 50~60 Hz
Weight(kg) 8 kg
Dimensions(WxDxH) 433(W)x381(D)x180(H)

Product details

OPTIZEN POP-V offers four measurement modes (Photometric Mode, Quantitative Mode, Spectrum Mode, Kinetics Mode).
The user can choose a suitable mode depending on the purpose to measure.
The embedded S/W, touch screen interface and application facilitate the use of the device.

Product information

  • Offering a help service with a graphic type.
  • Easily and quickly call up the information that is being measured or analyzed by registering it in you favorites.
  • Link it with PC by using OPTIZEN VIEW.
  • The measurement is possible in the optimal condition by checking the equipment’s operation time, lamp warm up condition and accumulated using time in real time.
  • The measurement monitoring is possible through choosing cell type without entering a mode and easily checking the current cell condition is possible through a change cell type icon according to the cell type condition or position.

Spectrophotometer single beam OPTIZEN™ POP

$0.00

OPTIZEN™ POP

THE SMART UV-VIS SPECTROPHOTOMETER

OPTIZEN POP SERIES are single-beam type spectrophotometers and offer stable performance and compact-size and reasonable price to the users.
The series are categorized into POP, POP-S, POP-V according to the specification of the products.

Main Characteristics

  • Checking and recording the temperature at the analysis moment by applying the temperature measurement system.
  • Offering ARM Cortex™ – A8 processor and supporting basic 16GB storage.
  • It can measure automatically lots of samples by using Multi Cell.
  • Supporting convenient voice service and volume control function.
  • Supporting network printer.

Specification

Photometrics System Single Beam Type
Light Source Tungsten Halogen Lamp & Deuterium Lamp
Spectral Bandwidth 1.8 nm (190 to 1100 nm)
Wavelength Range 190 to 1100 nm
Wavelength display 0.1 nm
Wavelength accuracy <± 0.5 nm
Wavelength repeatability <± 0.1 nm
Slew rate About 8,800 nm/min
Scan speed max 4,000 nm/min
Photometric range Absorbance : -3 to 3 Abs
Transmittance : 0 % to 300 %
Photometric accuracy ± 0.005 at 1.0 Abs
Stray lighty < 0.05 % Nal at 220 nm, NaNO₂ at 340 nm
Baseline stability <± 0.001 Abs/h
Baseline flatness ± 0.002 Abs
Monochromator Czerny-Turner type with 1200 lines/nm blazed grating
Lamp interchange Wavelength 340~410 nm (Default 370 nm)
Standard cell Holder Autometic Rotary type 8-position Multi-Cell Holder
Display 7 inch color LCD with touch screen;
Operating system(OS) Windows CE;
Power Requirement 100~240 V; 50~60 Hz
Weight(kg) 8 kg
Dimensions(WxDxH) 433(W)x381(D)x180(H)
Supplier Elite Scientific & Meditech Co.
Visit us www.elitetradebd.com

Product details

OPTIZEN POP offers four measurement modes (Photometric Mode, Quantitative Mode, Spectrum Mode, Kinetics Mode).
The user can choose a suitable mode depending on the purpose to measure.
The embedded S/W, touch screen interface and application facilitate the use of the device.

Products information

  • Offering a help service with a graphic type.
  • Easily and quickly call up the information that is being measured or analyzed by registering it in you favorites.
  • Link it with PC by using OPTIZEN VIEW.
  • The measurement is possible in the optimal condition by checking the equipment’s operation time, lamp warm up condition and accumulated using time in real time.
  • The measurement monitoring is possible through choosing cell type without entering a mode and easily checking the current cell condition is possible through a change cell type icon according to the cell type condition or position.

 

UV Vis double beam spectrophotometer, OPTIZEN™ Alpha

$0.00

UV-Vis Spectrophotometer double-beam type OPTIZEN™ Alpha, OPTIZEN™ Alpha UV-Vis Spectrophotometer double-beam type

OPTIZEN™ Alpha

The luxuriously designed OPTIZEN Alpha is spectrophotometer to use double-beam method.

OPTIZEN Alpha can grasp the quantitative characteristics such as density or purity by measuring transmittance or optical density according to wavelength of sample in the range of ultraviolet rays and visible ray.
OPTIZEN SERIES can be utilized from not only a general analysis experiment to but also a specialized research field and guarantee accurate measurement and excellent reproducibility, accordingly offer reliable results in the various fields such as environment, biotechnology, chemistry, etc.

Main Characteristics

  • A world-class measurement performance
  • Wide-size color screen (ALPHA: 8”)
  • Various cell compatibility and fast cell type choice
  • Automatic measurement of lots of samples by equipping multi-cell.
  • Convenient voice service and volume control
  • Emotional design

Specifications

Photometrics System Double-beam type
Spectral Bandwidth 1 nm (190 to 1100 nm)
Wavelength Range 190 to 1100 nm
Wavelength Setting 0.05 nm
Wavelength Accuracy ±0.3 nm (For entire range)
±0.1 nm (656.1 nm)
Wavelength Repeatability <± 0.1 nm
Slew Rate About 8,800 nm/min
Scan Speed max 6,000 nm/min
Photometric Range Absorbance : -4 to 4 Abs
Transmittance : 0 % to 400 %
Photometric Accuracy Less than ± 0.005 Abs at 1.0 Abs
Light Source Tungsten Halogen Lamp & Deuterium Lamp
Stray light < 0.02 % Nal at 220 nm, NaNO₂ at 340 nm
Photometric repeatability ± 0.0002 at 0.5 Abs
± 0.0006 at 1.0 Abs
± 0.001 at 2.0 Abs
Baseline stability < 0.0003 Abs/h
Baseline flatness <± 0.0005 Abs
Lamp interchange Wavelength 340~410 nm (Default 370 nm)
Power Requirement 100~240 V; 50~60 Hz
Operating system(OS) Windows 10 (Embedded PC);
Weight(kg) 14 kg
Dimensions(WxDxH) 520(W)x500(D)x200(H)
Standard cell Holder Autometic Rotary type 8-position Multi-Cell Holder
Supplier Elite Scientific & Meditech CO
Visit us www.elitetradebd.com

Product details

The previous single beam type spectrophotometer has a weak point of error occurrence in measuring a sample, because of the movement of a light source by time lag in measuring the strength of between a reference light and a light from sample.
To solve the problem, OPTIZEN Alpha was designed as a double-beam type spectrophotometer.
The system utilizes an additional reference beam to improve the measurement performance by compensating the intensity fluctuation of its light source.

Product information

  • Offering self-diagnosis function
  • Easily and quickly call up the information that is being measured or analyzed by registering it in you favorites.
  • Changing to the remote mode and then can link it with PC by using OPTIZEN VIEW.
  • The measurement is possible in the optimal condition by checking the equipment’s operation time, lamp warm up condition and accumulated using time in real time.
  • OPTIZEN Alpha’s login function can prevent the measured data from leaking to many and undesignated persons.

Assalamu Alaikum, Welcome to our company