Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99% (when MW>200 Dalton) |
Particles and bacteria rejection rate | >99% |
Output(25°C)**** | 15 L/hrs |
Pure water outlet | RO water |
Dimension LxWxH | 410x320x420 mm |
Weight | 15 kg |
Standard configuration | Main body (Including 1 set of cartridges) + TDS pen+ accessory bag |
Power Consumption (W) | 72 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Basic Water Purification System BBPS-201, Biolab, Canada
This basic series is ideal for wide range of applications. It produces RO, Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2M?.cm which completely meets the highest grade I standard.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet | RO water, Distilled water, Deionized water |
Temperature | 5-45°C |
Pressure | 1atm* |
Flow Procedure** | AC+DI+TF |
Ion rejection rate | – |
Organic rejection rate | – |
Particles and bacteria rejection rate | – |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | Utmost up to 2.0 L/min (less output with UF cartridge) |
Pure water outlet | Deionized water and Ultrapure water |
Water Quality Monitor | Portable TDS/conductivity test pen + on-line resistivity monitor |
DimensionLxWxH | 410x220x420 mm |
Weight | 20 kg |
Standard configuration | Main body (Including 1 set of cartridges)+ accessory bag |
Power Consumption (W) | 72 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **AC:active carbon, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by feed water quality. ****The output will decrease with terminal filter or UF cartridge. |
Deionized water quality: | |
Resistivity | >5 MΩ.cm |
Particle(>0.2µm) | <1/ml |
Ultrapure Water Quality: | |
TOC*** | <10 ppb |
Heavy metal ion | <0.1 ppb |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Basic Water Purification System BBPS-301, Biolab, Canada
This basic series is ideal for wide range of applications. It produces RO, Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2M?.cm which completely meets the highest grade I standard.
Food Industry, Beverage Industry, Agriculture, Boiler Feed, Disaster Relief Environmental, Hospital, Hotel, Marine, Military, Mining, Pharmaceutical, Power
Feed Water Requirements*: | |
Water Inlet |
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99% (when MW>200 Dalton) |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml (with optional 0.45+0.1µm PES terminal filter) |
Particles(>0.2µm) | <1/ml (with optional 0.45+0.1 µm PES terminal filter) |
Output(25°C)**** | 15 L/hrs |
Pure water outlet | RO water |
Water Quality Monitor | Portable TDS/conductivity test pen |
DimensionLxWxH | 410x220x420 mm |
Weight | 20 kg |
Standard configuration |
Main body (Including 1 set of cartridges)+15 liters tank+ TDS pen +accessory bag |
Power Consumption (W) | 48 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Ultrapure Water Quality: | |
Flow rate | 2.0 L/min (with pressure tank) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Basic Water Purification System BBPS-401, Biolab, Canada
This basic series is ideal for wide range of applications. It produces RO, Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2M?.cm which completely meets the highest grade I standard.
Laboratory, Manufacturing, Reefkeeping, Aquarium
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+DI |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%,when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Output(25°C)**** | 15 L/hrs |
Pure water outlet | RO and deionized water |
Water Quality Monitor | Portable TDS/conductivity test pen + on-line resistivity monitor |
DimensionLxWxH | 410x220x420 mm |
Weight | 20 kg |
Standard configuration | Main body (Including 1 set of cartridges)+15 liters tank+ TDS pen +accessory bag |
Power Consumption (W) | 48 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, TF:terminal microfiltration. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Deionized water quality: | |
Resistivity | >15-18.2 MΩ.cm |
Conductivity | 0.055-0.067µs/cm |
Particle(>0.2µm) | <1/ml |
Ultrapure Water Quality: | |
Flow rate | 2.0 L/min (with pressure tank) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Basic Water Purification System BBPS-501, Biolab, Canada
This basic series is ideal for wide range of applications. It produces RO, Deionized water and Ultrapure water. The organic rejection rate is greater than 99% using reverse osmosis. The resistivity reaches up to 18.2M?.cm which completely meets the highest grade I standard.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet |
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+DI+TF |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%,when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | 15 L/hrs |
Pure water outlet | RO water and Ultrapure water |
Water Quality Monitor | Portable TDS/conductivity test pen + on-line resistivity monitor |
Dimension LxWxH | 410x220x420 mm |
Weight | 20 kg |
Standard configuration | Main body (Including 1 set of cartridges)+15 liters tank+ TDS pen +accessory bag |
Power Consumption (W) | 48 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Deionized water quality: | |
Particle(>0.2µm) | <1/ml |
Ultrapure Water Quality: | |
Resistivity(25°C) | 18.2 MΩ.cm |
Heavy Metal Ion | – |
TOC*** | <10 ppb |
Heavy metal ion | <0.1 ppb |
Flow rate | 2.0 L/min (with pressure tank) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Large Capacity Water Purification System BCPS-101, Biolab, Canada
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Food Industry, Beverage Industry, Agriculture, Boiler Feed, Disaster Relief Environmental, Hospital, Hotel, Marine, Military, Mining, Pharmaceutical, Power
Feed Water Requirements*: | |
Water Inlet |
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%, when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml (with optional 0.2µm PES terminal filter) |
Particles(>0.2µm) | <1/ml (with optional 0.2 µm PES terminal filter) |
Output(25°C)**** | 45 L/hr |
Pure water outlet | RO water |
Water Quality Monitor | Portable TDS/conductivity test pen + on-line conductivity monitor |
DimensionLxWxH | 640x540x1110 mm |
Weight | 70 kg |
Standard configuration |
Main body (Including 1 set of cartridges)+ 2 built-in15 liters tank+ TDS pen +accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Large Capacity Water Purification System BCPS-201, Biolab, Canada
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Laboratory, Manufacturing, Reefkeeping, Aquarium
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC+DI+TF |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%, when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | 45 L/hr |
Pure water outlet | RO water and Deionized water |
DimensionLxWxH | 640x540x1110 mm |
Weight | 70 kg |
Standard configuration | Main body (Including 1 set of cartridges)+ 2 built-in15 liters tank +accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, TF:terminal microfiltration. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Deionized water quality: | |
Resistivity | >10-18.2 MΩ.cm |
Conductivity | 0.055-0.1µs/cm |
Particle(>0.2µm) | <1/ml |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Large Capacity Water Purification System BCPS-301, Biolab, Canada
Series: 300
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+AC+DI+TF |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%, when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | 45 L/hr |
Pure water outlet | RO water and Ultrapure water |
DimensionLxWxH | 640x540x1110 mm |
Weight | 70 kg |
Standard configuration | Main body (Including 1 set of cartridges)+ 2 built-in15 liters tank +accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure waters quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed waters TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Ultrapure Water Quality: | |
Resistivity(25°C) | 18.2 MΩ.cm |
Heavy Metal Ion | <0.1 ppb |
TOC*** | <10 ppb |
Particle (>0.2µm) | <1/ml |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Large Capacity Water Purification System BCPS-401, Biolab, Canada
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet |
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+RO+AC |
Output(25°C)**** |
1st stage RO water: 63 L/hr, 2nd stage RO water: 30 L/hr |
Pure water outlet | 1st and 2nd stage RO water |
Dimension LxWxH | 760x630x1190 mm |
Weight | 80 kg |
Standard configuration |
Main body (Including 1 set of cartridges) + built-in 2 tank (40L PE tank+2 gallon pressure tank)+ accessory bag |
Power Consumption (W) | 300 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Ultrapure Water Quality: | |
1st stage RO water’s TDS | TDS (ppm, mg/l) < TDS of tap water x 5% |
2nd stage RO water’s conductivity |
1-5µs/cm, Organic rejection rate>99% (when MW>200 Dalton), Particles and bacteria rejection rate>99% |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Large Capacity Water Purification System BCPS-501, Biolab, Canada
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Food Industry, Beverage Industry, Agriculture, Boiler Feed, Disaster Relief Environmental, Hospital, Hotel, Marine, Military, Mining, Pharmaceutical, Power
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+AC+RO+RO+AC |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%(when MW>200 Dalton) |
Particles and bacteria rejection rate | >99% |
Output(25°C)**** | 250 L/hr |
Pure water outlet | RO water |
DimensionLxWxH | 760x550x1210 mm |
Weight | 85 kg |
Standard configuration | Main body (Including 1 set of cartridges) + accessory bag |
Power Consumption (W) | 480 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure waters quality and cartridges life-span. **PF:polypropylene spun fiber, AC:active carbon, RO:reverse osmosis, DI:ion exchange, ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed waters TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Large Capacity Water Purification System BCPS-601, Biolab, Canada
This series is idea choice for general washing pure water. It’s output ranges from 45 to 500 liter of water an hour. It has automatic microcomputer controlling system, real-time animation mode display. Pipeline and fast-plug adapter with NSF authorization, assure high-quality ultrapure water.
Food Industry, Beverage Industry, Agriculture, Boiler Feed, Disaster Relief Environmental, Hospital, Hotel, Marine, Military, Mining, Pharmaceutical, Power
Feed Water Requirements*: | |
Water Inlet | Tap water or ground water |
Flow Procedure** | QZ+AC+SI+MF+RO |
Ion rejection rate | ≥98% |
Output(25°C)**** | 250 L/hr |
Dimension LxWxH | 1310x550x1750 mm |
Weight | 300 kg |
Power Consumption (W) | 3000 W |
Power Supply | AC380 V, 50 Hz |
Note | – |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Pure Water Supply System BPWS-102, Biolab, Canada
This system can be combined with any brand’s water purification system to supply pure water for specific equipment and it is easy to install and maintain. It has Independent power control and it can be run automatically according to the liquid level of the tank.
Applications
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Features
Specification
Shape & Volume of tank | Roundness: 500, 1000, 2000 L Square: 200 L |
Specifications of Pump: | |
Volume of Buffer Tank | 1 L |
Vertical self-priming height | 2 meters |
The Rated Stop Pressure | 0.3 Mpa/0.4 Mpa, 0.35 Mpa/0.4 Mpa |
Max Pressure/Pump Lift | About 0.3 Mpa/30 meters, About 0.35 Mpa/35 meters |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Pure Water Supply System BPWS-101, Biolab, Canada
This system can be combined with any brand’s water purification system to supply pure water for specific equipment and it is easy to install and maintain. It has Independent power control and it can be run automatically according to the liquid level of the tank.
Applications
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Features
Specification
Shape & Volume of tank | Roundness: 100, 200 L Square:80,120, 200 L |
Specifications of Pump: | |
Volume of Buffer Tank | 12 L |
Vertical self-priming height | 2 meters |
The Rated Stop Pressure | 0.45 Mpa/0.4 Mpa |
Max Pressure/Pump Lift | About 0.8 Mpa/80 meters |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Medium Water Purification System BDPS-101, Biolab, Canada
This medium series is an excellent choice of high-performance water purifying system. The self-flushing of the reverse osmosis membrane, extend the life of RO membrane. These systems are Level II password protected for all the parameters setting, and forbid any unauthorized settings change also It has multiple alarm functions.
Laboratory, Manufacturing, Reefkeeping, Aquarium
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+KDF+AC+RO+AC+DI |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%, when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Output(25°C)**** | 15 L/hr |
Pure water outlet | RO water and Deionized water |
Dimension LxWxH | 500x360x540 mm |
Weight | 22 kg |
Standard configuration | Main body (Including 1 set of cartridges)+15 liters tank+ accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, KDF:kinetic degradation fluxion, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, TF:terminal microfiltration. ***All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Deionized water quality: | |
Resistivity | >16-18.2 MΩ.cm |
Conductivity | – |
Particle(>0.2µm) | <1/ml |
Ultrapure Water Quality: | |
Heavy metal ion | <0.1 ppb |
Flow rate | 2.0 L/min (with pressure tank) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Medium Water Purification System BDPS-401, Biolab, Canada
This medium series is an excellent choice of high-performance water purifying system. The self-flushing of the reverse osmosis membrane, extend the life of RO membrane. These systems are Level II password protected for all the parameters setting, and forbid any unauthorized settings change also It has multiple alarm functions.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Flow Procedure** | PF+KDF+AC+RO+DI+TF |
Ion rejection rate | 96%-99% (New RO membrane) |
Organic rejection rate | >99%, when MW>200 Dalton |
Particles and bacteria rejection rate | >99% |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | 15 L/hr |
Pure water outlet | RO water and Ultrapure water |
Dimension LxWxH | 500x360x540 mm |
Weight | 25 kg |
Standard configuration | Main body (Including 1 set of cartridges)+15 liters tank+ accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, KDF:kinetic degradation fluxion, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Ultrapure Water Quality: | |
Resistivity(25°C) | 18.2 MΩ.cm |
Heavy Metal Ion | <0.1 ppb |
TOC*** | <10 ppb |
Particle (>0.2µm) | <1/ml |
Flow rate | 2.0 L/min (with pressure tank) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Medium Water Purification System BDPS-401, Biolab, Canada
This medium series is an excellent choice of high-performance water purifying system. The self-flushing of the reverse osmosis membrane, extend the life of RO membrane. These systems are Level II password protected for all the parameters setting, and forbid any unauthorized settings change also It has multiple alarm functions.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet | RO water, Distilled water, Deionized water |
Temperature | 5-45°C |
Pressure | 1 atm* |
Flow Procedure** | AC+DI+TF |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | Utmost up to 2.0 L/min (less output with UF cartridge) |
Pure water outlet | Deionized water and Ultrapure water |
DimensionLxWxH | 500x360x540 mm |
Weight | 20 kg |
Standard configuration | Main body (Including 1 set of cartridges)+ accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. ** AC:active carbon,DI:ion exchange,UV:ultraviolet,UF:ultrafiltration,TF:terminal microfiltration. ***Value of number will be influenced by feed water quality. ****The output will decrease with terminal filter or UF cartridge. |
Deionized water quality: | |
Resistivity | >5 MΩ.cm |
Ultrapure Water Quality: | |
Resistivity(25°C) | 18.2 MΩ.cm |
Heavy Metal Ion | <0.1 ppb |
TOC*** | <10 ppb |
Particle (>0.2µm) | <1/ml |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Laboratory Water Purification System BLPS-801, Biolab, Canada
Laboratory water purification system uses double stage reverse osmosis technology. It produces double stage RO water, Deionised, EDI and ultrapure water. These systems have 3 way on-line water quality sensor, multiple alarm with unique design and it has easy-to-replace cartridges pack unit.
Laboratory, Manufacturing, Reefkeeping, Aquarium, Laboratory, Research
Feed Water Requirements*: | |
Water Inlet | Tap water: TDS<200 ppm (Extra pretreatment filter is recommended if TDS>200 ppm) |
Temperature | 5-45°C |
Pressure | 1.0-4.0 Kgf/cm² |
Bacteria | <0.1 cfu/ml |
Output(25°C)**** | 10 L/hrs |
Pure water outlet | 2:Electro Deionization water, ultrapure water |
Dimension LxWxH | 500x360x540 mm |
Weight | 30 kg |
Standard configuration | Main body (Including 1 set of cartridges) + 20 liters tank+accessory bag |
Power Consumption (W) | 120 W |
Power Supply | AC110-220 V, 50/60 Hz |
Note |
*The feed water quality will influence the pure water’s quality and cartridges life-span. **PF:polypropylene spun fiber, KDF:kinetic degradation fluxion, AC:active carbon, RO:reverse osmosis, SF:softener, EDI: electro deionization, UV:ultraviolet, DI:ion exchange, UF:ultrafiltration, TF:terminal microfiltration. ***Value of number will be influenced by temperature and feed water quality. ****All the specifications are tested under the situation:feed water’s TDS=200ppm, 25°C, 50psi and 15% recovery rate. |
Ultrapure Water Quality: | |
Heavy Metal Ion | <0.1 ppb |
TOC*** | <30 ppb |
Feed Water Requirements: | |
Resistivity (25°C) | 18.2 MΩ.cm |
TOC* | – |
Particle (>0.1µm) | <1/ml |
Flow procedure** | PF+KDF+AC+RO+SF+EDI+DI+TF |
EDI water quality: | |
Resistivity*** | >5 MΩ.cm |
Silicon rejection rate | >99.9% |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Medical Class N Autoclave BAMN-401, Biolab, Canada
Designed for sterilization of solid instruments, medical class N autoclave is a non vacuum sterilizer which removes air from the chamber by thermodynamic air displacement. Safety features with door locking system, these autoclaves are ideal for small spaces.
Medical, Dental, Laboratory, Pharmaceutical, Research
Capacity | 3 L |
Sterilization Pressure | 0.22 Mp |
Sterilization Temperature | 134 °C |
Sterilization Time | 4 min |
Sterilization Cycle time | 11 min |
Required water | Distilled water or purified water |
Product Size | 300X190X350 mm |
Outer Dimension | 370x260x460 mm |
Gross Weight | 7.5 Kg |
Power | 0.5 KW |
Voltage | AC220/110V+10% |
Capacity | 3 L |
Sterilization Pressure | 0.22 Mp |
Sterilization Temperature | 134 °C |
Sterilization Time | 4 min |
Sterilization Cycle time | 11 min |
Required water | Distilled water or purified water |
Product Size | 300X190X350 mm |
Outer Dimension | 370x260x460 mm |
Gross Weight | 7.5 Kg |
Power | 0.5 KW |
Voltage | AC220/110V+10% |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Vertical Autoclave BAVT-604-A, Biolab, Canada
We offer a variety of vertical laboratory autoclaves for general purpose sterilization applications. Customers can choose from the range depending upon their application, volume and budgetary requirements. Features are designed specifically for lab based sterilizations used in research laboratories, pharmaceuticals, microbiology labs, food and chemical industries. High performance, reliable results and a longer life makes it an ideal choice.
Food industry, Chemical industry, Research, Laboratory, Pharmaceutical
Capacity | 100 L |
Sterilization Temperature | 105-135°C |
Sterilization Time | 1-999 min |
Sterilization mode |
1.Liquid 2.Liquid with warming 3.Solid 4.Instruments packed with cloth 5.Fabric 6.Rubber 7.Fast 8.Waste 9.Agar melting 10.Self defined |
Melting temperature | 60-100°C |
Melting time range | 1-999min |
Warming Temperature | 45-60°C |
Warming time range | 1-9999min |
Exhaust mode | Automatic internal discharging with an embedded steam collector |
Timer range | 0-6 days(Sterilization auto start up appointment) |
Pressure gauge range | -0.1-0.5Mpa |
Pressure | Safety valve set pressure:2.9bar |
Controller | “Smart II” fast speed microcomputer controller |
Working environment | 5-45°C,relatively humidity 10%-85% |
Chamber material | SUS304 |
Chamber(Diax H) | 400×809 |
Rate power supply(W) | 4600 |
Power requirement | 220V±10%,32A,50/60Hz |
Dimension(LxWxH,mm) | 620x680x1200 |
Baskets(DiaxH) | (360×220)x3 |
Safety device |
Seft-induction interlocking device, lid closing checking, over temperature protection system, dry scorch protection, over pressure protection, safety valve, over current and short circuit protection, electric leakage protection, scald protection, automatic failure-inspection system. |
Storage | up to 60 programs |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Best seller & Supplier in Bangladesh
Elite Scientific & Meditech Co.
Click for inquiry & purchase, Related products
Google, Facebook, LinkedIn, Twitter, Instagram, YouTube
Download Catalogue
Vertical Autoclave BAVT-603-A, Biolab, Canada
We offer a variety of vertical laboratory autoclaves for general purpose sterilization applications. Customers can choose from the range depending upon their application, volume and budgetary requirements. Features are designed specifically for lab based sterilizations used in research laboratories, pharmaceuticals, microbiology labs, food and chemical industries. High performance, reliable results and a longer life makes it an ideal choice.
Food industry, Chemical industry, Research, Laboratory, Pharmaceutical
Capacity | 80 L |
Sterilization Temperature | 105-135°C |
Sterilization Time | 1-999 min |
Sterilization mode |
1.Liquid 2.Liquid with warming 3.Solid 4.Instruments packed with cloth 5.Fabric 6.Rubber 7.Fast 8.Waste 9.Agar melting 10.Self defined |
Melting temperature | 60-100°C |
Melting time range | 1-999min |
Warming Temperature | 45-60°C |
Warming time range | 1-9999min |
Exhaust mode | Automatic internal discharging with an embedded steam collector |
Timer range | 0-6 days(Sterilization auto start up appointment) |
Pressure gauge range | -0.1-0.5Mpa |
Pressure | Safety valve set pressure:2.9bar |
Controller | “Smart II” fast speed microcomputer controller |
Working environment | 5-45°C,relatively humidity 10%-85% |
Chamber material | SUS304 |
Chamber(Diax H) | 400×709 |
Rate power supply(W) | 4600 |
Power requirement | 220V±10%,32A,50/60Hz |
Dimension(LxWxH,mm) | 620x680x1100 |
Baskets(DiaxH) | (360×280)x2 |
Safety device |
Seft-induction interlocking device, lid closing checking, over temperature protection system, dry scorch protection, over pressure protection, safety valve, over current and short circuit protection, electric leakage protection, scald protection, automatic failure-inspection system. |
Storage | up to 60 programs |
Images are reference only. Actual product may be different.