Elite Scientific & Meditech Co.
Autosampler for TOC Analyzer BANA-607, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory
Sample Bottle Volume | 60ml |
Maximum Number | 19 |
Injection Arm Stroke | 85 mm |
Ambient Temperature | 0-40 °C |
Relative Humidity | ≤85% |
Rated Power | 120W |
Power Adapter | AC 100-240V,50/60HZ |
Dimension | 265x373x395 mm |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Autosampler for TOC Analyzer BANA-605, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory
Sample Position | 20 |
Sample Volume | 30/60 ml |
Interface | USB |
Output | 120 W |
Power Supply | 100~240 V |
Frequency | 50/60 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
TOC Analyzer BANA-606, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory
Detector | NDIR |
Method | High Temperature Combustion |
Parameters | TC,TIC,TOC, NPOC |
Gas Requirement | Oxygen ≥99.995% |
Measurement Range | 0-30000mg/L |
Operation | PC software controlled |
Application | Liquid sample |
Power Supply | AC 220 V or AC 110 V, 50/60Hz, 1KW |
Dimension | 450x500x480 mm |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
TOC Analyzer BANA-604, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory.
Detector | NDIR |
Detection limit | 50 μg/l (ppb) |
Parameters | TC, TIC, TOC, NPOC |
Method | Wet Chemical Oxidation by UV |
Operation | PC Control |
Gas Requirement | Oxygen/Nitrogen≥ 99.995% |
Measurement Range | 0-10000 mg/l (ppm) |
Repeatability | 3% |
Maximum Salinity | 85 g/l |
Power | 200 W |
Power Supply | AC 220 V or AC 110 V |
Frequency | 50/60 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
TOC Analyzer BANA-603, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory.
Detector | NDIR |
Detection limit | 50 μg/l (ppb) |
Parameters | TC, TIC, TOC, NPOC |
Method | High Temperature Combustion |
Operation | PC Control |
Gas Requirement | Oxygen/Nitrogen≥ 99.995% |
Measurement Range | 0-30000 mg/l (ppm) |
Repeatability | 3% |
Maximum Salinity | 85 g/l |
Power | 200 W |
Power Supply | AC 220 V or AC 110 V |
Frequency | 50/60 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
TOC Analyzer BANA-602, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory.
Detector range | 0.001-1.500 mg/L (ppm) |
Detection limit | 1 ppb |
Max Tolerance | ±5% |
Analysis Time | 3 min |
Response Time | within 10 min |
Sample Temperature | 1-95°C |
Sample flow speed | 3 ml/min |
Relative humidity | ≤85% |
Drifiting | ±5% |
Repeatability tolerance | ≤3% |
Working Environment | 10-40°C with temperature change ±5°C/d |
Dimension | 440x220x300 mm |
Power | 100 W |
Power Supply | 220/110 V ±10% |
Frequency | 50 Hz +1 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
TOC Analyzer BANA-601, Biolab, Canada
TOC analyzer directly shows the total organic carbon content in water or liquid solutions. It is designed to make testing easier, reproducible and accurate. TOC analyzers maximize both sensitivity and productivity, making them the ideal choice for monitoring in wide range of aqueous samples.
Water for injection, Cleaning validation, Environmental, Chemical, Pharmaceutical Industries, Research, Laboratory
Detection limit | 1 ppb |
Max Tolerance | ±5% |
Analysis Time | 3 min |
Response Time | within 10 min |
Sample Temperature | 1-95°C |
Sample flow speed | 3 ml/min |
Relative humidity | ≤85% |
Drifiting | ±5% |
Repeatability tolerance | ≤3% |
Working Environment | 10-40°C with temperature change ±5°C/d |
Dimension | 440x220x300 mm |
Power | 100 W |
Power Supply | 220/110 V ±10% |
Frequency | 50 Hz +1 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Moisture analyzer BANA-505, Biolab, Canada
Moisture Analyzer measures the amount of moisture in a substance which particularly helps in food processing. These analyzers are also commonly used in environmental, pharmaceutical, and materials science labs. We provide a variety of moisture analyzer according to applications, features and customers requirements.
Food processing, Environmental, Pharmaceutical, Laboratory, Research, Medical, Hospitals, Agriculture, Industrial
Weighing Range | 10 g |
Weighing Repeatability | 0.05g |
Advised Sample Amount | 3-5 g |
Temperature | 50-180°C |
Temperature Program | Standard |
Pan Size | Φ100 mm |
Readability | 10 mg |
Terminal Control | Timing, Automatic |
Memory | Moisture%, Solid%, Weight, Time, Data etc |
Time Setting | 1-99minutes, 1 minute interval |
Dimension | 265x160x150 mm |
Packaging Size | 530x380x340 mm |
Weight | 4 / 6 kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Moisture analyzer BANA-505, Biolab, Canada
Moisture Analyzer measures the amount of moisture in a substance which particularly helps in food processing. These analyzers are also commonly used in environmental, pharmaceutical, and materials science labs. We provide a variety of moisture analyzer according to applications, features and customers’ requirements.
Food processing, Environmental, Pharmaceutical, Laboratory, Research, Medical, Hospitals, Agriculture, Industrial.
Weighing Range | 110 g |
Temperature | 40°C-230°C |
Operating Temperature Range | 5°C-35°C |
Temperature Set | 1°C |
Temperature Setting | 40°C-230°C By 1°C Step |
Moisture Range | 0.00%-100.0% |
Moisture Readability | 0.0001 |
Dry Range | 100.00%-0.00% |
Dry Residual Readability | 0.0001 |
Pan Size | Φ100 mm |
Readability | 0.001 g |
Interface | Cable, RS232/RJ45/USB |
Heat Source | HALOGEN LAMP |
Calibration | External Calibration |
Rechargeable Battery | No |
Temperature Sensor | PT-100 |
Display | 7 inch touch panel |
Operation Height | 275 mm |
The Chamber Height | 35 mm |
Time Setting | 1-99 min By 10 s |
Dimension | 215x195x415 mm |
Indicator Dimension | 200x75x135 mm |
Number of History | 20 |
Number of Storage | 20 |
Power | 400 W |
Balance | Output: 9 V |
Machine | Output: 24 V (Dual-drive) |
Power Supply | 220 V±15%, 110 V±15% / 50 Hz, 60 Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Halogen Moisture analyzer BANA-501, Biolab, Canada
Moisture Analyzer measures the amount of moisture in a substance which particularly helps in food processing. These analyzers are also commonly used in environmental, pharmaceutical, and materials science labs. We provide a variety of moisture analyzer according to applications, features and customers requirements.
Food processing, Environmental, Pharmaceutical, Laboratory, Research, Medical, Hospitals, Agriculture, Industrial.
Capacity | 110g/5mg |
Temperature | 40°C-199°C |
Operating Temperature Range | 5°C-35°C |
Temperature Set | 1°C |
Moisture Range | 0.00%-100.0% |
Moisture Readability | 0.001 |
Dry Range | 100.00%-0.00% |
Dry Readability | 0.001 |
Pan Size | Φ90 mm |
Readability | 5 mg |
Heat Source | HALOGEN LAMP-1 |
ATRO | 100%….999% |
ATRO 2 | 0%….999% |
Sensor | LOADCELL |
Temperature Sensor | PT-100 |
Packaging Size | 490x360x350 mm |
Number of Storage | 15 |
Weight | 7.5 kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
IR Carbon Sulphur Analyzer BANA-401, Biolab, Canada
IR Carbon Sulfur Analyzer is developed for the accurate and safe analysis of carbon and sulfur in inorganic samples. It can rapidly and accurately conduct content determination of carbon and sulfur in materials like steel, iron, alloy, nonferrous metals, etc. This is a high-tech product that integrates optical, electrical, computer, and analytical technology into one.
Mining, Construction Material, Food, Geology, Commercial Inspection, Automotive, Aviation, Steel Products, Minerals, Non-Ferrous Metals, Non-Ferrous Metal Alloys, Inorganic Materials, Research.
Working Environment | Room temp: 10°C to 30°C, relative Humidity less than 75% |
Carbon Measurement Range | w(C) 0.0005% – 6.0000% (can be extended to 99.999%) |
Sulphur Measurement Range | w(C) 0.0005% – 0.5000% (can be extended to 99.999%) |
Carbon Analysis Pool | One pool |
Sulphur Analysis Pool | one pool |
Carbon Analysis Precision | RSD<1% |
Sulphur Analysis Precision | RSD<1.5% |
Time of analysis | 25 to 60 seconds, could be adjusted. Around 35 seconds usually |
Sensitivity (The minimum readings) | C/s 0.1 ppm |
Electronic scale | Precision of read: 0.0001g |
Operational Software | WINDOWS XP English operating software |
Display function | The Carbon sulfur has a curve respectively |
Printing function | Print mode is diversification, provides two print modes of laboratory and testing, also can design printing formats |
Sample weight | 0.5 g |
Accessory Code | Name | 1 |
1600906006 | High frequency automatic inductive combustion furnace | 1 |
1600906007 | Electric Balance | 1 |
1600906008 | Computer | 1 |
1600906009 | Printer | 1 |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Hematology Analyzer BANA-301, Biolab, Canada
Blood Analyzer is used to determine components in blood. It is used by hospitals, medical labs, forensic labs and used to test for many things, such as blood cell counts, therapeutic drug monitoring, illegal drug use, blood typing, protein analysis, checking thyroid function, checking for the presence of antibodies.
Forensic Lab, Protein Analysis, Hospitals, Medical, Laboratory, Research, Industry, Pharmaceutical
Interface | Keyboard, mouse, RS232 serial port |
Test Principle | Impedance for cell counting and cyanide-free method for HGB |
Test Flow | 1 click to finish test automatically, 10µL blood is needed |
Clog Clear | High voltage and high pressure flush |
Parameter | 3 part differentiation of WBC, 20 parameters |
Histograms | WBC, RBC, PLT |
Sample mode | Venous, Capillary and prediluted blood |
Test Channel | 2 |
Throughput | 60 samples/hour |
Language | English, Spanish, Portuguese, etc. |
QC Mode | 3 level QC, L-J graph |
Calibration Mode | Auto mode and Manual mode |
Reference Range Type | Newborn, children, male, female and general |
Reagent | 2(Lyse and Diluent) |
Memory | 100,000 sample results |
Display | Touch screen LCD |
Printer | Thermal printer, supports external printer |
Dimension | 410x435x472 mm |
Weight | 21 kg |
Power Supply | 100~240 AC, 50/60 Hz |
Accessory Code | Name | Unit | 1 |
1600806018 | Power Cable (1.8 m) | pc | 1 |
1600806019 | Ground Cable | pc | 1 |
1600806020 | Serial Port Cable | pc | 1 |
1600806021 | Mouse | pc | 1 |
1600806022 | Keyboard | pc | 1 |
1600806023 | Touch Pen | pc | 1 |
1600806024 | Side Door Key | pc | 1 |
1600806025 | Hex Wrench (Φ 2.5) | set | 1 |
1600806026 | Service Pack | set | 1 |
1600806027 | Thermal Printer Paper (Width: 80 mm) | roll | 1 |
1600806028 | Diluent (20 L) | bottle | 1 |
1600806029 | Lyse Solution (500 mL) | bottle | 1 |
1600806030 | PB Cleanser (50 mL) | bottle | 1 |
1600806031 | E-Z Cleanser (50 mL) | bottle | 1 |
1600806032 | Diluent Cap Component | set | 1 |
1600806033 | Lyse Solution Cap Component | set | 1 |
1600806034 | Waste Bottle Cap Component | set | 1 |
1600806035 | Waste Bottle | pc | 1 |
Accessory Code | Name | Unit |
1600806006 | Thermal Printer Paper (Width: 80 mm) | roll |
1600806007 | PB Cleanser (50 mL) | bottle |
1600806008 | E-Z Cleanser (50 mL) | bottle |
1600806009 | Service Manual | pc |
1600806010 | Diluent (20 L) | bottle |
1600806011 | Lyse solution (500 mL) | bottle |
1600806012 | CBC-3D Blood QC High Level (3.0 mL) (R&D) | tube |
1600806013 | CBC-3D Blood QC Normal Level (3.0 mL) (R&D) | tube |
1600806014 | CBC-3D Blood QC Low Level (3.0 mL) (R&D) | tube |
1600806015 | Lyse solution (1 L) | bottle |
1600806016 | CBC-CAL PLUS Calibrator (3.0 mL) (R&D) | tube |
1600806017 | Barcode Scanner Assembly | pc |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Electrolyte Analyzer BANA-201, Biolab, Canada
Electrolyte Analyzer are designed to meet the needs of small to medium-size laboratories. It improves lab productivity while delivering sample results economically. It uses current ISE technology to make electrolyte measurements.
Hospital, Laboratory, Medical, Research
Type | Automatic |
Test Items | K, Na, Cl, Ca, pH |
Test Method | ISE Direct Method |
Test Time | ≤60S |
Sample Types | Serum, Plasma, Whole Blood, Ncurolymph and diluted urine |
Data Output | Built-in thermal printer, RS232 port |
Working Conditions | Temperature: 15~30°C, Humidity: ≤85% |
Sample Volume | 160 ul |
Dimension | 415x265x430 mm |
Weight | 7 / 10 kg |
Power | AC 100-240 V, 50±1 Hz, ≤35 W |
Accessory Code | Name | Capacity |
1600706006 | Turntable | |
1600706007 | Cal. Solution-A | 400 ml / bottle |
1600706008 | Cal. Solution-B | 200 ml / bottle |
1600706009 | CAL Solution C | 15 ml / bottle |
1600706010 | Reaction Solution C(TCO2) | 200 ml / bottle |
1600706011 | Electrode Activated Solution | 15 ml / bottle |
1600706012 | De-protein Solution | 15 ml / bottle |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Differential Thermal Analyzer BANA-101, Biolab, Canada
Differential Thermal Analysis is a technique which can measure the temperature difference and temperature relationship between the sample and the reference material in the process control temperature. Differential thermal analysis curves can describe the relationship of the temperature difference? T changes with the temperature or time between the sample and the reference material.
Metallurgy, Semiconductor, Pharmaceutical, Food Testing, Cement Chemistry, Environmental Research
Features
Display | 24 bit color 7 inch LCD touch screen display |
Temperature Range | Room temperature ~ 1150 °C |
Measuring Range | 0~±2000 μV |
DTA Precision | ±0.1 μV |
Heating Rate | 1 ~ 80°C/min |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ±0.1°C |
Temperature Repeatability | ±0.1°C |
Temperature Control: | |
Cooling Temperature | program control |
Constant Temperature | air-cooled program control |
Body Structure | Use the structure of the cover to replace the traditional lifting furnace, with high precision and easy operation |
Atmosphere Control | (optional) gas flow meter, atmosphere conversion device |
Data Interface | standard USB connector, supporting data line and operating Software |
Parameters of Standard | Equipped with reference substances, with a keycalibration fuction (User can correct the temperature) |
Baseline Adjustment | Users can adjust the baseline by changing baseline slope and intercept |
Work Power | AC 220V 50Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
UV Sterilization Cabinet BAIP-701, Biolab, Canada
UV Sterilization Cabinet are used to sterile various equipments. They are manufactured to the highest standards to ensure reliable, sterile results. It rapidly disinfect clinical equipment, furniture and electronic devices.
Hospital, Laboratory, House
Specification
Type | With Ozone |
UV Ray Wavelength | 253.7/184.9nm |
Sterilization Way | 2 sides of UV ray+1 side of Ozone |
Capacity | 200 L |
Power | 120 W |
UV Lamp Material | Quartz glass |
Shelves | Standard 2pc, can be optional |
Internal Size | 518x523x778 mm |
External Size | 750x663x1200 mm |
Packing Size | 875x788x1265 mm |
Gross Weight | 100 kg |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Ozone UV Sterilization Cabinet BAIP-601, Biolab, Canada
The ozone UV sterilization cabinet can sterilize the appliances that are not resistant to high temperature such as glass enamel cups, plastics, ceramics, machinery and equipment, production supplies, currency, non-woven fabrics and so on.
Sterilization of Glass, enamel cups, plastics, ceramics, machinery and equipments, production supplies, currency, non-woven fabrics, composite paper, packing boxes, packaging bags, appliance , cleaning appliances, mold, tableware, container, towels, work clothing, clothing, shoes, packaging materials, raw materials, solid It is suitable for banks, hotels, restaurants, schools, production workshops with hygienic requirements, public places that need to be sterilized , and family rooms.
Capacity | 70 L |
Sterlization Method | Ozone |
Shelves | 2pcs, optional 2pcs ,adjustable |
Work zone Material | 304 stainless steel, 1.0mm thick |
Main Body Material | Cold-rolled steel with coating |
Ozone concentration | >60mg/m3 |
Sterilization Level | Medium and low Level |
Indicator Bacteria | Escherichia Coli, Staphy lococcus Aureus , Candida Albicans |
Index | Each point of the log kill value should be ≥ 3.00 |
Sterilization Rate | Over 99.99%,For all kinds of bacteria, viruses, fungi |
Control System | Automatic |
Working Condition | (a) Ambient temperature range 5℃-40℃ (b) Relative humidity is not more than 85% (c) Atmospheric pressure 70 Kpa-106Kpa (d) No flammable, corrosive gas or conductive dust around |
Internal Size (WxDxH) | 398x398x452 mm |
External Size (WxDxH) | 495x501x760 mm |
Package Size (WxDxH) | 726x620x860 mm |
Gross Weight | 50 kg |
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
PP Reagent Cabinet BAIP-501, Biolab, Canada
PP reagent cabinet is specially designed for the storage and anti leakage requirements of strong acid and strong corrosive chemicals
Hospital, School/ University Laboratory, Pharmaceutical Laboratory.
Power Supply | AC110/220V士10%, 50/60Hz |
Package Size (WxDxH) | 985x535x1915mm |
Gross Weight | 72 kg |
External Size (WxDxH) | 900x450x1800 mm (can be customized according to customer needs) |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Air Sterilizer BAIP-401, Biolab, Canada
Air purifiers are devices that are used for removing contaminating particles from air, making the air cleaner to breathe.
Applications
Hospital, small clinic, laboratory, office, meeting room and houses.
Features
Specification
Filter | Primary Filter, HEPA filter |
HEPA Filter | 99.99% efficiency at 0.3pm |
UV Lamp | Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination |
Optimal Space | ≤20m2 |
Noise | ≤58 dB |
Consumption | 240 W |
Adjustable Air Speed | 3 levels |
Cleanness At Outlet | Class 100 |
Gross Weight | 78 kg |
Package Size (WxDxH) | 1800x440x1050 mm |
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
External Size (WxDxH) | 900x120x1500 mm |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Pathology Workstation BAIP-301, Biolab, Canada
Workstations are use during dissections, autopsies, necropsies, and other pathological procedures. It include grossing/trimming stations and dissection tables may also include a built-in sink and ventilation system
Hospital pathology department, Pathology laboratory.
Exhaust Airflow Volume | 500~600m3/h |
Main Body Material | 304 stainless steel |
Work Table Material | 304 stainless steel |
Package Size (WxDxH) | 1160x890x2170 mm |
Gross Weight | 250 kg |
Working Area Size (WxDxH) | 895x430x900 mm |
External Size (WxDxH) | 1000x750x1950 mm |
Consumption | 250 W |
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue
Clean Booth BAIP-201, Biolab, Canada
Clean booth is used as air purifier and it limits the contamination due to pollutants, thus providing partial high clean environment
Pharmaceutical, Experimental drugs, Processing formula, electronics, medicine, food, precision instruments, biochemical and chemical industries.
Clean Level | ISO 5(Class100), Class A |
HEPA Filter | 99.999% efficiency at 0.3pm |
FFU Nos. | 4 pcs |
Control System | Microprocessor control system |
Rectangular Tube Material | Aluminium alloy |
Wall Material | Anti-static dustproof curtain |
Blower | Built-in centrifugal blower, speed adjustable |
UV Lamp | 40W Emission of 253.7 nanometers with UV timer |
Illumination Lamp | 16Wx1 LED Lamp, lllumination:2:500lux |
Air Velocity | 0.1-0.6m/s,average 0.45m/s |
Internal Size (WxDxH) | 1920x1380x2140 mm |
External Size (WxDxH) | 2000x1500x2530 mm |
Package Size (WxDxH) | 2110x930x920 mm 2280x660x500 mm |
Consumption | 800 W |
Gross Weight | 390 kg |
Net Weight | 355 kg |
Noise | ≤75 dB |
Power Supply | AC220V±10%, 60Hz/50Hz;110V±10%, 60Hz |
Images are reference only. Actual product may be different.
Click Our Social Network Links
Download Catalogue